Direct Antiglobulin Test, Complete Study: Michigan Medicine Laboratories (MLabs) test DATIN

Michigan Medicine Laboratories (MLabs) test DATIN, CPT 86880. Specimen: 7 mL whole blood. Turnaround: 1 - 72 hours.

Direct Antiglobulin Test, Complete Study is Michigan Medicine Laboratories (MLabs) test code DATIN, billed with CPT 86880. Specimen: 7 mL whole blood. Turnaround time: 1 - 72 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories, OHSU Laboratory Services, Labcorp, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeDATIN
CPT86880 x2
LOINC—
Specimen7 mL whole blood
Volume7 mL whole blood
Turnaround time1 - 72 hours
Storage / transportAmbient

Also known as: Coombs Antibody; Coombs Test; IgG DAT; C3 DAT; DAT Study; Direct Coombs`

Use

To detect IgG immunoglobulin and/or complement adherence to red cells, as seen in immune hemolytic anemia or in a delayed hemolytic transfusion reaction. Positive tests will be further evaluated for bound and unbound antibody specificities associated with Cold Hemagglutinin Disease, Warm Autoimmune Hemolytic Anemia, and delayed reaction to transfusion. Positive tests will be further evaluated to determine the specific type(s) of protein adhering to the red cells and present in the serum (indirect test).

Collection instructions

Collect specimens in two pink top tubes. Send intact specimens at room temperature. Specimens are unacceptable if collected in serum separator tube, contaminated, or grossly hemolyzed. Specimens sent for Blood Bank testing cannot be split for use by other laboratories.

Reference range

Negative

Limitations

Use of red top tubes or serum separator tubes may cause false positive reactions.

Section

Blood Bank

Performed

Monday - Friday, 8:00am - 4:00pm

NY State approved

No

Alternate specimens

IN-HOUSE: Lavender top tube (intact specimen) may be substituted for Pink top. All other specimen types are unacceptable. MLABS: Pink top tube (intact specimen) is preferred; the following are acceptable: lavender top (glass or plastic), red top (glass only). Plastic red top tubes will be rejected without exception. [10/03; rev 4/04]

Performing Laboratory

Transfusion Medicine

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86880

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation