Cryofibrinogen Evaluation: Michigan Medicine Laboratories (MLabs) test CRGSP

Michigan Medicine Laboratories (MLabs) test CRGSP, CPT 82585, 82595. Specimen: 3 mL EDTA plasma AND 5 mL serum (15 mL whole blood in a red top tube). Turnaround: 2 - 10 days.

Cryofibrinogen Evaluation is Michigan Medicine Laboratories (MLabs) test code CRGSP, billed with CPT 82585, 82595. Specimen: 3 mL EDTA plasma AND 5 mL serum (15 mL whole blood in a red top tube). Turnaround time: 2 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeCRGSP
CPT82585, 82595
LOINC—
Specimen3 mL EDTA plasma AND 5 mL serum (15 mL whole blood in a red top tube)
Volume3 mL EDTA plasma AND 5 mL serum (15 mL whole blood in a red top tube)
Turnaround time2 - 10 days

Also known as: Cryoprecipitate; Cryocrit; Cryoprotien

Use

Evaluating patients with vasculitis, glomerulonephritis, and lymphoproliferative diseases and evaluating patients with macroglobulinemia or myeloma in whom symptoms occur with cold exposure.

Collection instructions

Specimens must be maintained at 37 degrees C +/- 2 degrees C from the time they are collected until plasma or serum is separated from the cells. LAVENDER TOP: Collect specimen in a lavender top tube (plasma gel tube is unacceptable). Blood may be centrifuged immediately in a room temperature centrifuge. If this is not possible, the specimens can be placed in a 37 degrees C water bath until they can be centrifuged. Specimen should be centrifuged at 37 degrees (pass to Chem to process- they have a centrifuge in a 37 degree incubator); ambient (24 degrees) is acceptable if 37 degrees is not plausible. Aliquot plasma into a plastic vial. After the plasma is removed, place in the refrigerator; please note on the requisition or as a footnote in the computer that the specimen was processed at 37 degrees C. RED TOP: Collect specimen in a red top tube (serum separator tube is unacceptable). Within one minute, specimen must be placed into a 37 degrees C +/- 2 degrees C incubator or water bath. Leave specimen at 37 degrees C until specimen is clotted. Specimen should be centrifuged at 37 degrees (pass to Chem to process- they have a centrifuge in a 37 degree incubator); ambient (24 degrees) is acceptable if 37 degrees is not plausible. Aliquot serum into a plastic vial. After the serum is removed, place in the refrigerator; please note on the requisition or as a footnote in the computer that the specimen was processed at 37 degrees C. If the necessary specimen processing equipment is not available, the patient should have the specimen collected at a University of Michigan Taubman Center Blood Drawing station.

Reference range

CRYOGLOBULIN: Negative (positives reported as a percent). CRYOFIBRINOGEN: Negative. Quantitation and immunotyping will not be performed on positive cryofibrinogen. An interpretive report will be provided.

Section

Sendout Testing

Performed

Monday - Friday

Contraindications

This test is not useful for general screening of a population without a clinical suspicion of cryoglobulinemia.

NY State approved

No

Performing Laboratory

Sendout Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 82585, 82595

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation