Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Chromosomal Microarray, Prenatal, Amniotic Fluid/Chorionic Villus Sampling

Chromosomal Microarray, Prenatal, Amniotic Fluid/Chorionic Villus Sampling: Michigan Medicine Laboratories (MLabs) test CMAP

Michigan Medicine Laboratories (MLabs) test CMAP, CPT 81229. Specimen: 20-30 mL amniotic fluid; 20-30 mg of CVS in 15 mL of RPMI. Turnaround: 10-21 days.

Chromosomal Microarray, Prenatal, Amniotic Fluid/Chorionic Villus Sampling is Michigan Medicine Laboratories (MLabs) test code CMAP, billed with CPT 81229. Specimen: 20-30 mL amniotic fluid; 20-30 mg of CVS in 15 mL of RPMI. Turnaround time: 10-21 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeCMAP
CPT81229
LOINC—
Specimen20-30 mL amniotic fluid; 20-30 mg of CVS in 15 mL of RPMI
Volume20-30 mL amniotic fluid; 20-30 mg of CVS in 15 mL of RPMI
Turnaround time10-21 days

Also known as: CMA

Collection instructions

Amniotic fluid: 1. Optimal timing for specimen collection is during 14 to 18 weeks of gestation, but specimens collected at other weeks of gestation are also accepted. Provide gestational age at the time of amniocentesis. 2. Discard the first 2 mL of amniotic fluid. 3. Send the specimen and CMA patient history form to Specimen Processing CVS: 1. Collect specimen by the transabdominal or transcervical method. 2. Transfer chorionic villi to a Petri dish containing transport medium (Such as CVS Media [RPMI] and Small Dish). 3. Using a stereomicroscope and sterile forceps, assess the quality and quantity of the villi and remove any blood clots and maternal decidua. Transfer to a screw capped transport tube and send to Specimen Processing along with the CMA patient history form. A maternal blood sample is requested (separate order for Mayo test PPAP) and should be sent along with the Amniotic fluid/CVS

Reference range

Interpretive report provided

Limitations

This test does not detect all types and instances of uniparental disomy. This test is not designed to detect low-level mosaicism, although it can be detected in some cases. This test does not detect point alterations, small deletions or insertions below the resolution of this assay, or other types of variants such as epigenetic changes. The results of this test may reveal incidental findings not related to the original reason for referral. In such cases, studies of additional family members may be required to help interpret the results.

Section

Sendout Testing

Performed

Monday - Friday

NY State approved

No

Performing Laboratory

Sendout Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81229

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation