Cytogenetics, Chromosomal Microarray Analysis, Tumor: Michigan Medicine Laboratories (MLabs) test CGATU
Michigan Medicine Laboratories (MLabs) test CGATU, CPT 81277. Specimen: 3 cm(3). Turnaround: 3 weeks.
Also known as: Array CGH (aCGH), Tumor; Microarray CGH, Tumor; Chromosomal Microarray Analysis, Tumor; Array for Neoplasia, Tumor; Cytogenomic Microarray, Neoplasia; Cancer Cytogenomic Microarray, Tumor; SNP Array, Tumor; Cancer Array
Use
Chromosomal Microarray Analysis assay detects DNA copy number gains (including amplification) and losses as well as regions of copy neutral loss of heterozygosity (CN-LOH) by SNP analysis. This assay is particularly useful for malignant conditions with a low mitotic index and when limited material is available for standard cytogenetic analysis. At least 30% of malignant cells must be present in the sample submitted for Chromosomal Microarray Analysis assay.
Collection instructions
Specimen transport should be arranged so that the specimen is received by MLabs the same day it is collected. Call for a STAT courier if necessary. Collect tumor specimen using aseptic technique. Place tissue in Chromosome Media in a Nalgene cryogenic vial, available from MLabs. Specimen must be shipped at at room temperature and received by the laboratory within 24 hours of collection. Do not allow specimen to overheat or freeze. Alternatively, fresh specimen can be frozen at less than or equal to -20 degrees C and shippped on dry ice by overnight courier. Small samples with insufficient amount of DNA or necrotic samples with greatly degraded DNA are not acceptable. Most insurance carriers require prior authorization for payment. Testing will not begin until insurance prior authorization is received, it is confirmed that prior authorization is not required, or the patient has agreed to pay out of pocket. A completed Michigan Medicine Request and Consent for Genetic Testing form is required and is available by calling 800-862-7284 or online: https://mlabs.umich.edu/media/188 .
Reference range
Interpretive report provided.
Limitations
Although Chromosomal Microarray Analysis is a powerful diagnostic tool for the evaluation of chromosomal copy number changes, this assay will not detect balanced chromosomal aberrations, imbalance of regions not represented on the microarray, or point mutations. A karyotype or FISH test is more appropriate when a translocation or inversion is suspected. Also, chromosome or FISH analysis is more appropriate if a STAT result is required. Although copy number changes present at 20% of cells can generally be detected using a SNP array, the quality of solid tumor specimens is very variable. Therefore, this test requires 30% or greater tumor burden in the specimen. Interpretation of Chromosomal…
Section
Cytogenetics
Performed
Monday - Friday
Contraindications
Chromosomal Microarray Analysis should not be ordered for follow-up studies to determine remission status or the presence of minimal residual disease.
NY State approved
No
Performing Laboratory
Cytogenetics
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 81277
- Bone marrow Cancer Chromosome Microarray
- Bone Marrow Chromosome Analysis with Reflex SNP Array
- Chromosome Analysis, Bone Marrow with Reflex to Genomic Microarray
- Chromosome Analysis, Leukemic Blood with Reflex to Genomic Microarray
- Cytogenetics, Chromosomal Microarray Analysis for Melanoma, FFPE Tissue
- Cytogenetics, Chromosomal Microarray Analysis, Blood or Bone Marrow
- Cytogenetics, Chromosomal Microarray Analysis, FFPE tissue
- Cytogenomic Molecular Inversion Probe Array FFPE Tissue - Oncology
- Cytogenomic SNP Microarray - Oncology
- Leukemic Blood Cancer Chromosome Microarray + SNP
- Microarray-Tumor Reveal® FFPE
- Multiple Myeloma Enriched Microarray and Multiple Myeloma FISH
- Multiple Myeloma Enrichment SNP Microarray−Oncology (Reveal®)
- OBSOLETE Chromosomal Microarray Analysis, Tumor
- SNP Microarray−Oncology (Reveal®)
- Microarray-Tumor Reveal® FFPE
- Multiple Myeloma Enriched Microarray and Multiple Myeloma FISH
- Reveal SNP Microarray - Oncology
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation