Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Apolipoprotein E Genotyping

Apolipoprotein E Genotyping: Michigan Medicine Laboratories (MLabs) test APOEG

Michigan Medicine Laboratories (MLabs) test APOEG, CPT 81401. Specimen: 3 mL whole blood in the original tube; 100 mcL at a concentration of 75 ng/mcL. Include concentration and volume on the . Turnaround: 6 - 10 days.

Apolipoprotein E Genotyping is Michigan Medicine Laboratories (MLabs) test code APOEG, billed with CPT 81401. Specimen: 3 mL whole blood in the original tube; 100 mcL at a concentration of 75 ng/mcL. Include concentration and volume on the tube. Turnaround time: 6 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Quest Diagnostics, Labcorp, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeAPOEG
CPT81401
LOINC—
Specimen3 mL whole blood in the original tube; 100 mcL at a concentration of 75 ng/mcL. Include concentration and volume on the tube
Volume3 mL whole blood in the original tube; 100 mcL at a concentration of 75 ng/mcL. Include concentration and volume on the tube
Turnaround time6 - 10 days
Storage / transportBlood: Ambient preferred, refrigerated or frozen acceptable. (stable 4 days) Extracted DNA: Frozen (stable 1 year)

Also known as: Apo E Genotyping; Apolipoprotein E Genotyping by DNA Analysis; Apo E2 Gene Detection; Apo E3 Gene Detection; Apo E4 Gene Detection

Use

Determining the specific apolipoprotein E (APOE) genotypes in patients with type III hyperlipoproteinemia.

Collection instructions

Collect blood in a lavender top tube. Refrigerate and send intact blood in the original tube within 48 hours of collection

Reference range

Interpretive report provided. This test detects the Apo E2, E3, and E4 genes.

Limitations

This assay will not detect all of the mutations that cause type III hyperlipoproteinemia. Therefore, the absence of a detectable mutation does not rule out the possibility that an individual is a carrier of or affected with this disease. This assay cannot predict or rule out the development of Alzheimer disease in an individual. Rare polymorphisms exist that could lead to false-negative or false-positive results. If results obtained do not match the clinical findings, additional testing should be considered.

Section

Sendout Testing

Performed

Tuesday, Thursday

Contraindications

In the absence of specific information regarding advances in the knowledge of mutation characteristics for a particular disorder, the current literature indicates that genetic tests for inherited disease need only be conducted once per lifetime.

NY State approved

No

Alternate specimens

ACD (yellow top) is acceptable. Extracted DNA: Additional Information: DNA must be extracted in a CLIA-certified laboratory or equivalent and must be extracted from a specimen type listed as acceptable for this test (including applicable anticoagulants). Our laboratory has experience with Chemagic, Puregene, Autopure, MagnaPure, and EZ1 extraction platforms and cannot guarantee that all extraction methods are compatible with this test. If testing fails, one repeat will be attempted, and if unsuccessful, the test will be reported as failed and a charge will be applied. If applicable, specific gene regions that were unable to be interrogated due to DNA quality will be noted in the report.

Performing Laboratory

Sendout Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81401

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation