Acylcarnitines, Quantitative, Plasma: Michigan Medicine Laboratories (MLabs) test ACARN

Michigan Medicine Laboratories (MLabs) test ACARN, CPT 82017. Specimen: 0.1 mL plasma. Turnaround: 5 - 10 days.

Acylcarnitines, Quantitative, Plasma is Michigan Medicine Laboratories (MLabs) test code ACARN, billed with CPT 82017. Specimen: 0.1 mL plasma. Turnaround time: 5 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories, Quest Diagnostics.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeACARN
CPT82017
LOINC—
Specimen0.1 mL plasma
Volume0.1 mL plasma
Turnaround time5 - 10 days
Storage / transportFrozen (-20°C): 30 days; Refrigerated (2-8°C): 7 days

Also known as: Acylcarnitine Analysis Plasma; Acylcarnitine Profile; Acylcarnitine Plasma

Use

The analysis of acylcarnitine profiles is performed for use in screening of inborn errors of metabolism, specifically fatty acid oxidation disorders, and certain organic acidemias (acidurias). In some cases, results are diagnostic of a specific disorder, while in other cases, further testing may be needed.

Collection instructions

Collect specimen in a green top tube (sodium heparin), Centrifuge within 2 hours of collection and aliquot plasma and freeze (preferred) or store at refrigerated temperature (2-8°C) for up to 7 days. Grossly hemolytic specimens are unacceptable. Plasma specimens stored at room temperature greater than 2 hours are unacceptable.

Reference range

Interpretive report provided. Acylcarnitines, Quantitative, Plasma Reference Ranges Analyte Age ≤7 days Age 8 days to 7 years Age › 7 years C2, Acetylcarnitine 2.14 – 15.89 2.00 – 27.57 2.00 – 17.83 C3, Propionylcarnitine <0.55 <1.78 <0.88 C4, Isobutyryl-/Butyrylcarnitine <0.46 <1.06 <0.83 C5:1, Tiglylcarnitine <0.05 <0.11 <0.11 C5, Isovalerylcarnitine <0.38 <0.63 <0.51 C6, Hexanoylcarnitine <0.14 <0.23 <0.17 C5-OH, 3-Hydroxyisovalerylcarnitine <0.08 <0.12 <0.10 C8, Octanoylcarnitine <0.19 <0.45 <0.78 C3-DC, Malonylcarnitine <0.09 <0.14 <0.26 C10, Decanoylcarnitine <0.27 <0.91 <0.88 C5DC, Glutarylcarnitine <0.06 <0.10 <0.11 C12, Dodecanoylcarnitine <0.18 <0.35 <0.26 C14:1, Tetradecenoylcarnitine <0.16 <0.35 <0.18 C14, Tetradecanoylcarnitine <0.11 <0.15 <0.12 C16, Hexadecanoylcarnitine <0.36 <0.52 <0.23 C16-OH, 3-Hydroxyhexadecanoylcarnitine <0.10 <0.07 <0.06 C18:1, Octadecenoylcarnitine <0.25 <0.45 <0.39 C18, Octadecanoylcarnitine <0.10 <0.12 <0.14 C18-OH, 3-Hydroxyoctadecanoylcarnitine <0.03 <0.05 <0.03 Acylcarnitines, Quantitative, Plasma Reference Ranges Analyte Age ≤7 days Age 8 days to 7 years Age › 7 years C2, Acetylcarnitine 2.14 – 15.89 2.00 – 27.57 2.00 – 17.83 C3, Propionylcarnitine <0.55 <1.78 <0.88 C4, Isobutyryl-/Butyrylcarnitine <0.46 <1.06 <0.83 C5:1, Tiglylcarnitine <0.05 <0.11 <0.11 C5, Isovalerylcarnitine <0.38 <0.63 <0.51 C6, Hexanoylcarnitine <0.14 <0.23 <0.17 C5-OH, 3-Hydroxyisovalerylcarnitine <0.08 <0.12 <0.10 C8, Octanoylcarnitine <0.19 <0.45 <0.78 …

Section

Biochemical Genetics

Performed

Tuesday, Friday

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 82017

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation