Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Invitae BRCA1 and BRCA2 STAT Panel

Invitae BRCA1 and BRCA2 STAT Panel (Women's Health): Labcorp test 898047

Labcorp test 898047, CPT 81162. Specimen: Whole blood or ORAcollect Dx OCD-100 buccal swabs. Turnaround: 7 - 14 days.

Invitae BRCA1 and BRCA2 STAT Panel is Labcorp test code 898047, billed with CPT 81162. Specimen: Whole blood or ORAcollect Dx OCD-100 buccal swabs. Turnaround time: 7 - 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code898047 (Women's Health)
CPT81162
LOINC55752-0, 77202-0
SpecimenWhole blood or ORAcollect Dx OCD-100 buccal swabs
Volume4 mL whole blood or 2 ORAcollect Dx OCD-100 buccal swabs
Minimum volume3 mL whole blood or 2 ORAcollect Dx OCD-100 buccal swabs
ContainerLavender-top (EDTA) tube or ORAcollect Dx OCD-100 buccal swabs
Turnaround time7 - 14 days 10 - 14 days 7 - 14 days
Storage / transportFor blood and buccal, maintain specimen at room temperature or refrigerate at 4°C. Do not freeze.

Test includes

This test includes the following genes: BRCA1 and BRCA2 .

Use

This test analyzes the BRCA1 and BRCA2 genes, which are associated with adult-onset hereditary breast and ovarian cancer syndrome (HBOC). It is appropriate for breast cancer patients with upcoming cancer-related breast surgeries and/or treatment, and genetic testing may inform decisions such as lumpectomy versus mastectomy, single versus double mastectomy, or use of other treatments (such as use of PARP inhibitors or other chemotherapy regimens). Depending on the individual’s clinical and family history, a broader panel may be appropriate. This test is specifically designed for heritable germline mutations and is not appropriate for the detection of somatic mutations in tumor tissue.

Methodology

Next-generation sequencing to identify genetic variants, including single nucleotide variants (SNVs), insertions, deletions and copy number variants (CNVs). Confirmation of the presence and location of reportable variants is performed as needed based on stringent criteria using one of several validated orthogonal approaches.

Collection instructions

Standard phlebotomy; follow ORAcollect Dx OCD-100 buccal swab collection instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to buccal collection.

Stability

Whole blood: 90 days at room temperature or 4°C Buccal: 60 days at room temperature

Causes for rejection

Frozen or hemolyzed specimen; quantity not sufficient for analysis or in improper container; specimen from an individual who has undergone allogeneic bone marrow transplant

Special instructions

Test orders must include an attestation that the provider has the patient's informed consent for genetic testing.

Limitations

Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations, including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change with time if more information becomes available. False positive or false negative results may occur for reasons that include: rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism, mislabeled samples or erroneous representation of…

LOINC map

Result codeResult nameUnitsResult LOINC
STAT BRCA1/BRCA2 Gene Panel899522Important Note77202-0
STAT BRCA1/BRCA2 Gene Panel899537Additional Information55752-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81162

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation