Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Toluene, Occupational Exposure, Whole Blood

Toluene, Occupational Exposure, Whole Blood: Labcorp test 790580

Labcorp test 790580, CPT 84600. Specimen: Whole blood. Turnaround: 10 - 14 days.

Toluene, Occupational Exposure, Whole Blood is Labcorp test code 790580, billed with CPT 84600. Specimen: Whole blood. Turnaround time: 10 - 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code790580
CPT84600
LOINC9637-0
SpecimenWhole blood
Volume20 mL
Minimum volume7 mL
ContainerGreen-top (heparin) tube
Turnaround time10 - 14 days
Storage / transportRefrigerate; specimen may also be frozen.

Also known as: Toluol

Use

Evaluate exposure to toluene

Methodology

Headspace gas chromatography/flame ionization detection (GC/FID)

Collection instructions

Collect adequate number of tubes to obtain the required specimen volume. Tubes should be completely filled to prevent loss of volatile compound into headspace. Collect prior to last shift of workweek.

LOINC map

Result codeResult nameUnitsResult LOINC
790568Toluenemg/l9637-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84600

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation