Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Manganese, RBC and Plasma

Manganese, RBC and Plasma: Labcorp test 790540

Labcorp test 790540, CPT 83785. Specimen: Packed RBCs and plasma. Turnaround: 5 - 9 days.

Manganese, RBC and Plasma is Labcorp test code 790540, billed with CPT 83785. Specimen: Packed RBCs and plasma. Turnaround time: 5 - 9 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code790540
CPT83785
LOINC5682-0, 5683-8
SpecimenPacked RBCs and plasma
Volume3 mL each plasma and packed RBCs
ContainerRoyal blue-top (EDTA) metal-free tube; metal-free transfer tubes
Turnaround time5 - 9 days
Storage / transportRoom temperature

Use

This test is used to evaluate manganese stores.

Methodology

Inductively coupled plasma/mass spectrometry (ICP/MS)

Collection instructions

Both packed cells and plasma are required. Separate before shipping. Failure to separate may cause rejection due to hemolysis of red cells and contamination of the plasma. Transfer RBCs and plasma into separate plastic, acid-washed, trace metal-free tubes. Specimen must be received at the testing facility within five days of collection.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Failure to separate plasma and red cells; specimen received more than five days after collection

Reference range

Manganese plasma: <1.7 ng/mL Manganese RBC: See table. Age Male (ng/mL) Female (ng/mL) 0 to 1 y Not established Not established 2 to 12 y 10.1–22.8 10.1–22.8 13 to 30 y 7.6–17.8 9.1–23.6 31 to 50 y 7.6–17.8 8.4–21.5 51 to 60 y 7.4–17.0 7.9–18.9 61 to 110 y 7.4–17.0 8.6–20.3

LOINC map

Result codeResult nameUnitsResult LOINC
Manganese, Plasmang/ml5683-8
Manganese, RBCng/ml5682-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83785

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation