Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Methylmalonic Acid, Serum or Plasma

Methylmalonic Acid, Serum or Plasma: Labcorp test 706961

Labcorp test 706961, CPT 83921. Specimen: Serum or plasma. Turnaround: 3 - 6 days.

Methylmalonic Acid, Serum or Plasma is Labcorp test code 706961, billed with CPT 83921. Specimen: Serum or plasma. Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code706961
CPT83921
LOINC13964-2
SpecimenSerum or plasma
Volume2 mL
Minimum volume0.6 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (heparin) tube
Turnaround time3 - 6 days
Storage / transportRefrigerate.

Use

Serum methylmalonic acid (MMA) measurement is used to evaluate individuals with signs and symptoms associated with vitamin B 12 deficiency or congenital methylmalonic academia.

Methodology

Liquid chromatography/tandem mass spectrometry (LC/MS-MS)

Collection instructions

Separate serum or plasma from cells within one hour of collection.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen19 days
Freeze/thaw cyclesStable x3

Causes for rejection

Plasma from a light blue-top or yellow-top tube; citrate interferes with assay

Reference range

0−378 nmol/L

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
706797Methylmalonic Acid, Serumnmol/L13964-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83921

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation