Succinyladenosine (CSF): Labcorp test 631649
Labcorp test 631649. Specimen: Cerebrospinal fluid (CSF) from a lumbar puncture (LP). Turnaround: 10 - 14 days.
Use
CSF Succinyladenosine is useful for diagnosing adenylosuccinate lyase (ADSL) deficiency, an autosomal recessive defect of purine metabolism. Clinical indications for testing include late or early onset seizures, delayed development of mental and movement abilities, autistic behavior, and encephalopathy with an occasional lack of myelination. There are three forms of adenylosuccinate lyase deficiency: 1. The neonatal form, the most severe form, can show signs and symptoms before birth, including impaired growth during fetal development and microcephaly. Newborns have severe encephalopathy, lack of movement, difficulty feeding, life-threatening respiratory problems and intractable…
Methodology
HPLC/UV Detection
Collection instructions
Single-tube collection (if no additional testing is ordered): Collect the entire sample into a single sterile tube from a standard LP. Important: If additional tests are ordered concurrently, use the Labcorp 5-Tube CSF Collection Kit (PeopleSoft No. 125218). Each kit contains five microcentrifuge tubes. CSF collection protocol: Collect CSF starting from the first drop directly into the first tube. Do not aliquot from a pooled sample. Fill tubes in numerical order, to the volume listed below: Tube 1: 0.5 mL Tube 2: 1.0 mL Tube 3: 1.0 mL (contains antioxidants to preserve sample integrity) Tube 4: 1.0 mL Tube 5: 1.0 mL Handling after collection: If no blood contamination, place tubes on dry ice immediately at bedside. If blood contamination is present, centrifuge immediately (before freezing). Transfer clear CSF to new, correspondingly labeled tube, then place the tube on dry ice immediately. Label tubes with patient name and ID number, leaving the tube number viewable. Complete Labcorp Neurochemistry request form. Include test required, sample date and date of birth.
Stability
| Temperature | Period |
|---|---|
| Frozen | 14 days |
Special instructions
This test currently is not approved for use in New York state.
Limitations
Note: Bloody CSF and samples received thawed may compromise analyte stability and lead to inaccurate results. Results should be interpreted in the context of clinical findings and other laboratory data. If results are inconsistent with the clinical presentation, consultation with the laboratory is recommended.
View this test on Labcorp's website → · Last checked 2026-11-29
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.