Sound Lab Consultants › National Lab Test Directory › Labcorp › Allergic Bronchopulmonary Aspergillosis (ABPA) Profile I

Allergic Bronchopulmonary Aspergillosis (ABPA) Profile I: Labcorp test 607660

Labcorp test 607660, CPT 82785, 86001, 86003. Specimen: Serum. Turnaround: 4 - 6 days.

Allergic Bronchopulmonary Aspergillosis (ABPA) Profile I is Labcorp test code 607660, billed with CPT 82785, 86001, 86003. Specimen: Serum. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code607660
CPT82785; 86001; 86003
LOINC19113-0, 26954-8, 51662-5, 6025-1, 8251-1
SpecimenSerum
Volume2 mL
Minimum volume1 mL ( Note : This volume does not allow for repeat testing.)
ContainerGel-barrier tube
Turnaround time4 - 6 days
Storage / transportRoom temperature

Test includes

Immunoglobulin E, Total; Aspergillus fumigatus Antibody, IgE; Aspergillus fumigatus Antibody, IgG

Use

This profile serves as an aid in the diagnosis of allergic bronchopulmonary aspergillosis (ABPA).

Methodology

See individual test information.

Collection instructions

Transfer separated serum to a plastic transport tube.

Stability

See individual test information.

Causes for rejection

See individual test information.

Limitations

Non-fumigatus strains account for ABPA in some cases, and IgG to these strains may not be detected by the ImmunoCAP® A. fumigatus IgG assay. Labcorp's Aspergillus Precipitating Antibodies, IgG [606846] assay includes most species associated with Aspergillus-related lung disease in the United States.

LOINC map

Result codeResult nameUnitsResult LOINC
602444Class Description8251-1
002173Immunoglobulin E, TotalIU/mL19113-0
602471M003-IgE Aspergillus fumigatuskU/L6025-1
607590Aspergillus fumigatus IgGmg/L26954-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82785, 86001, 86003

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation