Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Hepatitis C Virus (HCV) NS5A Drug Resistance Assay

Hepatitis C Virus (HCV) NS5A Drug Resistance Assay: Labcorp test 550325

Labcorp test 550325, CPT 87900, 87902. Specimen: Plasma (preferred) or serum, frozen. Turnaround: 10 - 14 days.

Hepatitis C Virus (HCV) NS5A Drug Resistance Assay is Labcorp test code 550325, billed with CPT 87900, 87902. Specimen: Plasma (preferred) or serum, frozen. Turnaround time: 10 - 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code550325
CPT87900; 87902
LOINC73655-3
SpecimenPlasma (preferred) or serum, frozen
Volume2 mL
Minimum volume1 mL
ContainerShip in plasma preparation tubes (PPT™) or screw-capped polypropylene frozen transport tubes.
Turnaround time10 - 14 days
Storage / transportFreeze.

Also known as: HCV Drug Resistance; NS5A Resistance Analysis

Use

Assessment of drug susceptibility by nucleic acid sequencing of a patient's hepatitis C virus (HCV) to the NS5A inhibitors. Assay should be used for patients with documented HCV genotype 1.

Methodology

Polymerase chain reaction (PCR) amplification and DNA next generation sequencing

Collection instructions

Collect specimen in two PPT™ tubes, gel-barrier tubes, or lavender-top (EDTA) tubes. Do not use green-top (heparin) tubes. Centrifuge specimen within six hours of collection, remove serum/plasma, transfer specimen to polypropylene screw-capped tubes, and freeze. Specimens drawn into PPT™ tubes need to be centrifuged within six hours and frozen. Ship frozen . To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Causes for rejection

PPT™ not centrifuged; insufficient volume; heparinized plasma; nonfrozen specimens; specimens exposed to repeated freeze/thaw cycles; specimen received in "pop-top" or "snap-cap" tube

Special instructions

Please indicate the patient's HCV genotype (1a or 1b) on the test request form. Submit a separate frozen specimen for each test ordered.

Limitations

This procedure may not be successful when the HCV viral load is <500 IU/mL. This assay requires an HCV genotype of either 1a or 1b. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
HCV NS5A Drug Resistance Assay550317HCV NS5A Drug Resistance Assay73655-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87900, 87902

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation