Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Hepatitis C Virus (HCV) FibroSure®

Hepatitis C Virus (HCV) FibroSure®: Labcorp test 550123

Labcorp test 550123, CPT 81596. Specimen: Serum. Turnaround: 3 - 5 days.

Hepatitis C Virus (HCV) FibroSure® is Labcorp test code 550123, billed with CPT 81596. Specimen: Serum. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code550123
CPT81596
LOINC48792-6, 48793-4, 48794-2, 48795-9, 48796-7, 62364-5
SpecimenSerum
Volume3.5 mL
Minimum volume2 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 5 days
Storage / transportSpecimen can be stored refrigerated at 2°C to 8°C for 72 hours and frozen at -70°C for seven days. Frozen samples are stable for one freeze/thaw cycle.

Also known as: ActiTest; FibroSure®; FibroTest

Use

Assessment of liver status following a diagnosis of HCV. Baseline determination of liver status before initiating HCV therapy. Posttreatment assessment of liver status six months after completion of therapy. Noninvasive assessment of liver status in patients who are at increased risk of complications from a liver biopsy.

Methodology

See individual test components.

Collection instructions

Separate serum from cells within two hours of collection, and transfer serum to a transfer tube.

Stability

TemperaturePeriod
Room temperature72 hours (stability provided by manufacturer or literature reference)
Refrigerated72 hours (stability provided by manufacturer or literature reference)
Frozen7 days (stability provided by manufacturer or literature reference)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer or literature reference)

Patient preparation

Patient should be fasting for at least eight hours.

Causes for rejection

Gross hemolysis; gross lipemia; improper labeling; nonfasting specimen; patient younger than 14 years of age

Reference range

See tables. METAVIR Group Scoring System Fibrosis Stage (FibroTest) Range F0−No fibrosis 0.00−0.21 F0−F1 >0.21−0.27 F1−Portal fibrosis >0.27−0.31 F1−F2 >0.31−0.48 F2−Bridging fibrosis with few septa >0.48−0.58 F3−Bridging fibrosis with many septa >0.58−0.72 F3−F4 >0.72−0.74 F4−Cirrhosis >0.74−1.00 Activity Stage (ActiTest) Range A0−No activity 0.00−0.17 A0−A1 >0.17−0.29 A1−Minimal activity >0.29−0.36 A1−A2 >0.36−0.52 A2−Moderate activity >0.52−0.60 A2−A3 >0.60−0.63 A3−Severe activity >0.63−1.00

Special instructions

The patient's age and gender must be included on the test request form.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. The FDA has determined that such clearance or approval is not necessary.

LOINC map

Result codeResult nameUnitsResult LOINC
550102Fibrosis Score48795-9
550132Fibrosis Stage48794-2
550103Necroinflammat Activity Score48792-6
550133Necroinflammat Activity Grade48793-4
550398Methodology:62364-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81596

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation