Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Rheumatoid Arthritis (RA) Profile with Reflex to SeroNeg RAdx4

Rheumatoid Arthritis (RA) Profile with Reflex to SeroNeg RAdx4: Labcorp test 520298

Labcorp test 520298, CPT 86200, 86431. Specimen: Serum. Turnaround: 8 - 11 days.

Rheumatoid Arthritis (RA) Profile with Reflex to SeroNeg RAdx4 is Labcorp test code 520298, billed with CPT 86200, 86431. Specimen: Serum. Turnaround time: 8 - 11 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code520298
CPT86200; 86431
LOINC11572-5, 57093-7
SpecimenSerum
Volume3 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time8 - 11 days
Storage / transportRefrigerate.

Also known as: RA Profile (Rheumatoid Factor and Anti-CCP) with Reflex to SeroNeg RAdx4 (Anti-MCV, Anti-CEP1, Anti-Sa, Anti-CarP)

Test includes

This test is reflexive. RF by Turbidimetry and Anti-CCP are performed and reported. If both are negative (i.e., <14 IU/mL and <20 Units, respectively), the SeroNeg RAdx4 (Anti-MCV, Anti-CEP1, Anti-Sa, and Anti-CarP) is performed.

Use

This RA Profile with Reflex to SeroNeg RAdx4 is a novel profile for rheumatoid arthritis that if negative for traditional markers, RF and anti-CCP, reflexes to four novel markers (anti-MCV, anti-CEP-1, anti-Sa, anti-CarP) that comprise the SeroNeg RAdx4 profile, which is designed to enhance diagnosis of RA and early RA as well as predict disease severity. If anti-MCV and/or anti-Sa positivity is present, the disappearance or decrease of these antibodies with treatment is associated with less radiographic progression. In pre-clinical RA, positivity of anti-CEP-1 along with anti-CCP antibodies significantly raises the risk of imminently developing clinical RA. Anti-CarP may predict the…

Methodology

Enzyme-linked immunosorbent assay (ELISA); Turbidimetry

Collection instructions

Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen60 days
Freeze/thaw cyclesStable x1

Causes for rejection

Grossly hemolyzed; bacterial contamination; lipemic, icteric, non-serum specimen types

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Rheumatoid Factor by Turb RDLIU/mL11572-5
Anti-CCP Ab, IgG + IgA (RDL)Units57093-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86200, 86431

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation