Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Chromosome Analysis, Whole Blood (Constitutional) With Reflex for Y Deletion Analysis

Chromosome Analysis, Whole Blood (Constitutional) With Reflex for Y Deletion Analysis: Labcorp test 512138

Labcorp test 512138. Specimen: Whole blood. Turnaround: 25 - 28 days.

Chromosome Analysis, Whole Blood (Constitutional) With Reflex for Y Deletion Analysis is Labcorp test code 512138. Specimen: Whole blood. Turnaround time: 25 - 28 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code512138
CPTCall client services.
LOINC31208-2, 55199-4, 62358-7, 62360-3, 62361-1, 77314-3
SpecimenWhole blood
Volume5 mL (adults), 2 mL (neonates) for each tube
Minimum volume2 mL each tube
ContainerGreen-top (sodium heparin) tube and lavender-top (EDTA) tube
Turnaround time25 - 28 days
Storage / transportSpecimen should be delivered to the laboratory immediately . Maintain specimen at room temperature. Specimens may be refrigerated if there is a delay in shipment. Do not freeze.

Use

This test evaluates infertility, hypogonadism, Klinefelter syndrome, and balanced or unbalanced chromosomal rearrangements that correlate with oligospermia/azoospermia.

Methodology

Routine lymphocyte culture, chromosome analysis of 20 metaphases with preparation and analysis of multiple karyotypes. Other banded preparations are made as needed. Fluorescence in situ hybridization (FISH) applied as needed. If chromosomes are normal, multiplex polymerase chain reaction (PCR) using primers corresponding to the following sequence tagged sites (loci) on the Y chromosome: SY14(SRY), SY81(DYS271), SY86(DYS148), SY84(DYS273), SY182 (KALY), SY121(DYS212), SYPR3(SMCY), SY124(DYS215), SY127(DYS218), SY128(DYS219), SY130(DYS221), SY133(DYS223), SY134(DYS224), SY145(DYF51S1), SY152(DYS236), SY242(DAZ), SY208(DAZ), SY254(DAZ), SY255(DAZ), SY157(DYS240), and controls SMCX and ZFX/ZFY.

Collection instructions

Using sterile technique, collect 5 mL of whole blood into a green-top (sodium heparin) tube or syringe and collect 5 mL whole blood into a lavender-top (EDTA) tube or syringe. Invert the tube several times to prevent coagulation. Specimens should be sent the same day as collected. Use of improper anticoagulant and/or frozen specimen cannot be processed.

Causes for rejection

Upon receipt, suitability of specimen will be determined by the Cytogenetics laboratory.

Special instructions

Pertinent medical findings must accompany request for chromosome analysis. Include the patient's name, age and suspected diagnosis.

Limitations

False positive or negative results may occur for reasons that include genetic variants, blood transfusions, bone marrow transplantation or erroneous representation of family relationships. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
512543Specimen Type31208-2
512544Cells Counted62361-1
512545Cells Analyzed62360-3
512546Cells Karyotyped55199-4
512547GTG Band Resolution Achieved62358-7

View this test on Labcorp's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation