Labcorp test 511414, CPT 81253. Specimen: Whole blood, buccal swab, amniotic fluid, or chorionic villus sample (CVS) (Submission of maternal blood is required for. Turnaround: 14 - 21 days.

GJB2 Sequencing, Family-targeted (Single Exon Sequencing−Known Mutation) is Labcorp test code 511414, billed with CPT 81253. Specimen: Whole blood, buccal swab, amniotic fluid, or chorionic villus sample (CVS) (Submission of maternal blood is required for fetal testing.). Turnaround time: 14 - 21 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code511414
CPT81253
LOINC35300-3
SpecimenWhole blood, buccal swab, amniotic fluid, or chorionic villus sample (CVS) (Submission of maternal blood is required for fetal testing.)
Volume7 mL whole blood, 4 buccal swabs, 10 mL amniotic fluid, or 20 mg CVS
Minimum volume3 mL whole blood, 2 buccal swabs, 5 mL amniotic fluid, or 10 mg CVS
ContainerLavender-top (EDTA) tube or yellow-top (ACD) tube; sterile plastic conical tube, two confluent T-25 flasks for fetal testing or LabCorp buccal swab kit
Turnaround time14 - 21 days
Storage / transportMaintain specimen at room temperature or refrigerate at 4°C.

Also known as: Connexin 26; Hearing Loss ( GJB2 )

Test includes

This test only covers the exon or amplicon that harbors the variant(s) of interest. Other regions of the gene will not be examined.

Use

Detects known familial mutations in the connexin 26 ( GJB2 ) gene associated with nonsyndromic sensorineural hearing loss (NSHL). This option is available when the mutation is known and can be documented by the ordering physician. If the mutation cannot be documented, please order full gene sequencing.

Methodology

DNA sequencing

Causes for rejection

Frozen specimen; hemolysis; quantity not sufficient for analysis; improper container; wet buccal swab

Limitations

This method does not reliably detect mosaic variants; large deletions; large duplications, inversions, or other rearrangements; deep intronic variants or variants outside of the regions targeted by this analysis. It may be affected by allele-dropout, it may not allow determination of the exact numbers of T/A or microsatellite repeats, and it does not allow any conclusion as to whether two heterozygous variants are present on the same or on different chromosome copies.

LOINC map

Result codeResult nameUnitsResult LOINC
511415GJB2 Family Targeted35300-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81253

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation