Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › UGT1A1 Irinotecan Toxicity

UGT1A1 Irinotecan Toxicity (Onc): Labcorp test 511200

Labcorp test 511200, CPT 81350. Specimen: Whole blood or LabCorp buccal swab kit (buccal swab collection kit contains instructions for use of a buccal swab). Turnaround: 5 - 7 days.

UGT1A1 Irinotecan Toxicity is Labcorp test code 511200, billed with CPT 81350. Specimen: Whole blood or LabCorp buccal swab kit (buccal swab collection kit contains instructions for use of a buccal swab). Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code511200 (Onc)
CPT81350
LOINC41044-9, 72486-4
SpecimenWhole blood or LabCorp buccal swab kit (buccal swab collection kit contains instructions for use of a buccal swab)
Volume5 mL whole blood or LabCorp buccal swab kit
Minimum volume3 mL whole blood or two buccal swabs
ContainerLavender-top (EDTA) tube, yellow-top (ACD) tube, or LabCorp buccal swab kit
Turnaround time5 - 7 days
Storage / transportMaintain whole blood specimen at room temperature for 7 days or refrigerated for 1 month, or frozen for 2 years. Maintain buccal swabs at room temperature for 6 months.

Also known as: Camptosar®; Irinotecan

Use

Irinotecan (Camptosar®) is used, or under evaluation, in a broad spectrum of solid tumors, and is often prescribed for treating patients with metastatic cancer of the colon or rectum, especially when 5-fluorouracil treatment has not been entirely successful. Severe toxicity (eg, grade 4 neutropenia) is commonly observed in cancer patients receiving irinotecan who carry the UGT1A1 *28 allele, also called TA. This test result will provide valuable information to physicians prior to initiating or modifying treatment or supplementing treatment with additional drugs. UGT1A1 variants have also been reported in patients with disorders of bilirubin metabolism, such as Crigler-Najjar Types I and II,…

Methodology

Polymerase chain reaction (PCR); capillary electrophoresis

Collection instructions

Whole blood preferred. Collect specimen in a lavender-top (EDTA) or yellow-top (ACD) tube, or use a buccal swab kit. Ship whole blood specimen at room temperature or frozen. Ship buccal swab collection kit at room temperature.

Stability

TemperaturePeriod
Room temperatureWhole blood: 7 days; buccal swab: 6 months
RefrigeratedWhole blood: 1 month
FrozenWhole blood: 2 years

Causes for rejection

Hemolysis; quantity not sufficient for analysis; improper container; single buccal swab; wet buccal swab

Limitations

The current test will only test the TATA box polymorphism of the UGT1A1 gene. The other polymorphisms of this gene will not be detected. This test was developed, and its performance characteristics determined, by LabCorp. It has not been cleared or approved by the US Food and Drug Administration (FDA).

LOINC map

Result codeResult nameUnitsResult LOINC
511202Result:41044-9
N/A511200UGT1A1 Irinotecan Toxicity41044-9
511200UGT1A1 Irinotecan Toxicity41044-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81350

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation