Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Chromosome Analysis, Instability Syndrome

Chromosome Analysis, Instability Syndrome: Labcorp test 511045

Labcorp test 511045. Specimen: Whole blood. Turnaround: 13 - 18 days.

Chromosome Analysis, Instability Syndrome is Labcorp test code 511045. Specimen: Whole blood. Turnaround time: 13 - 18 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code511045
CPTContact CPT coding department at 800-222-7566, ext 6-8400.
LOINC55199-4, 62361-1
SpecimenWhole blood
Volume5 mL (adults), 2.5 mL (neonates)
Minimum volume2.5 mL
ContainerGreen-top (sodium heparin) tube
Turnaround time13 - 18 days
Storage / transportMaintain specimen at room temperature. Specimen may be refrigerated if there is a delay in shipment. Do not freeze.

Test includes

Specific instability testing (see Methodology); G-banded chromosome analysis

Use

This test is used for chromosome analysis with DEB-induced breakage to assist in the diagnosis of Fanconi anemia (FA).

Methodology

Spontaneous and induced (DEB/mitomycin C) chromosome breakage rate increase

Collection instructions

Using sterile technique, collect 5 mL of blood into a green-top (sodium heparin) tube or syringe. Invert the tube several times to prevent coagulation. Specimens should be sent the same day as collected. Use of improper anticoagulant and/or frozen specimen cannot be processed.

Causes for rejection

Upon receipt, suitability of specimen will be determined by the Cytogenetics laboratory.

Special instructions

If cord blood or fetal blood is received, Test No. 510180 will be added to exclude maternal origin of the sample obtained.

Limitations

This result does not exclude the possibility of subtle rearrangements below the resolution of cytogenetics or congenital anomalies due to other etiologies. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Chromosome, Instability Syn511009Cells Counted62361-1
Chromosome, Instability Syn511016Cells Karyotyped55199-4

View this test on Labcorp's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation