NASHnext™: Labcorp test 504960
Labcorp test 504960, CPT 0468U. Specimen: Serum and whole blood. Turnaround: 5 - 7 days.
Also known as: Liver disease; Metabolic Dysfunction-Associated Steatohepatitis (MASH); Metabolic Dysfunction-Associated Steatotic Liver Disease (MASLD); NIS4™; Non-alcoholic fatty liver disease (NAFLD); Non-alcoholic steatohepatitis (NASH)
Use
Labcorp's NASHnext is a non-invasive blood test that reflects both NASH activity and fibrosis in a single score by combining the results of four individual NASH-associated biomarkers. The intended use of this test is for predicting likelihood of at-risk NASH. (NASH is now referred to as metabolic dysfunction-associated steatohepatitis (MASH)).
Methodology
NIS4 test produces a score from the results of the following assays: HbA1c, Whole Blood, Roche; a2-macroglobulin, serum, Roche; miR34a, serum RT-qPCR; CH13L1/YKl40 serum, immunoassay.
Collection instructions
Note: Please draw whole blood sample first. Whole Blood: Draw blood into lavender-top (EDTA) tube and ensure tube is completely filled. Gently invert tube six times to mix. Label tube with patient name, identification number, date and time of collection. The usual precautions in the collection of venipuncture should be observed. The sample must be free of clots. Samples with any hematocrit disorders can lead to erroneous results. Serum : Separate serum from cells within 30 to 60 minutes after collection. Transfer specimen to two separate plastic transport tubes. Freeze and ship frozen.
Stability
| Temperature | Period |
|---|---|
| Period | Whole Blood |
| Serum | Room temperature |
| 14 days | 2 hours |
| Refrigerated | 14 days |
| 2 hours | Frozen |
| 14 days | 1 week: -20 °C |
| 180 days: -70°C | Freeze/thaw cycles |
| Stable x3 | Stable x3 |
Patient preparation
Patient must fast at least 12 hours before the blood draw.
Causes for rejection
Gross hemolysis; unfrozen serum; serum collected in an incorrect tube type; serum that is not separated and frozen within two hours; serum stored at -20°C for more than one week
Limitations
This test was validated and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 504964 | NIS4 Test | 93692-2 |
View this test on Labcorp's website → · Last checked 2026-11-29
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.