Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Cortisol:Cortisone Ratio Profile, LC/MS-MS

Cortisol:Cortisone Ratio Profile, LC/MS-MS: Labcorp test 503715

Labcorp test 503715, CPT 82533, 82542. Specimen: Serum (preferred) or plasma. Turnaround: 6 - 10 days.

Cortisol:Cortisone Ratio Profile, LC/MS-MS is Labcorp test code 503715, billed with CPT 82533, 82542. Specimen: Serum (preferred) or plasma. Turnaround time: 6 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code503715
CPT82533; 82542
LOINC14159-8, 2143-6
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube, red-top tube, lavender-top (EDTA) tube or green-top (heparin) tube
Turnaround time6 - 10 days
Storage / transportFreeze (preferred) or refrigerate.

Use

The mineralocorticoid receptor binds cortisol as an active ligand, yet in normal people cortisol levels are not related to sodium retention. While in vitro the mineralocorticoid receptor has a similar affinity as aldosterone and cortisol, and in vivo cortisol is found in concentrations 100 to 1000 times higher than those of aldosterone, 11β-hydroxysteroid dehydrogenase 2 protects the mineralocorticoid receptor by reducing cortisol to cortisone, which is not an active ligand. This enzyme occurs in cells that contain the receptor. A similar enzyme is present in other tissues but works more slowly and backwards, converting cortisone to cortisol. Defects in this system can cause hypertension…

Methodology

High-pressure liquid chromatography (HPLC)/tandem mass spectrometry

Collection instructions

Serum/plasma must be separated from cells within 45 minutes of venipuncture. Send serum/plasma in a plastic transport tube

Stability

TemperaturePeriod
Room temperature2 days
Refrigerated2 days
Frozen7 days

Limitations

Results of this test are for investigational purposes only. The performance characteristics of this assay have been determined by LabCorp. The result should not be used as a diagnostic procedure without confirmation of the diagnosis by another medically established diagnostic product or procedure.

LOINC map

Result codeResult nameUnitsResult LOINC
Cortisol, Serum LCMSug/dL2143-6
Cortisone, Serum, LCMSug/dL14159-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82533, 82542

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation