P53 Mutation Analysis: Labcorp test 489590
Labcorp test 489590, CPT 81352. Specimen: Peripheral blood or bone marrow. Turnaround: 10 days.
Also known as: CLL
Use
More than 10% of patients with B-CLL have a dysfunctional p53 gene. Patients may have p53 mutations, a p53 deletion, or both. Mutations and deletions in p53 predict poor survival in B-CLL patients (median survival 6-31 months) versus those patients without p53 abnormalities (median survival of patients with normal karyotype >100 months). Several studies have demonstrated that alkylating agents, purine analogs and some monoclonal therapies are ineffective in treating CLL patients with p53 mutations and/or deletions. Finally, chemotherapy can cause p53 gene alterations, can exhibit new alterations of p53.
Methodology
Samples are enriched for B-cells. Susequently, DNA is isolated from the samples and amplified by polymerase chain reaction (PCR). Exons 5-9 and the flanking intronic regions (-6 and +15) of the TP53 gene are analyzed by bi-directional direct DNA sequencing using capillary gel electrophoresis and fluorescence detection.
Collection instructions
Ship specimen with an ice pack. Specimen should arrive in the laboratory within 5-7 days of collection. If specimen is to be stored prior to shipment, store at 2°C to 8°C. Indicate date and time of collection on the request form.
Causes for rejection
Specimen does not meet collection criteria: frozen whole blood, marrow, or cell pellet; leaking tube; clotted blood or marrow; grossly hemolyzed specimen, or otherwise visably degraded; contamination by another specimen; specimens containing suspicious foreign material
Limitations
The assay can detect a mutation present in at least 20% of a B-cell-enriched sample. False positive or negative results may occur for reasons that include genetic variants, blood transfusions, or somatic heterogeneity of the tissue sample. This test was developed and its performance characteristics determined by Esoterix Genetic Laboratories, LLC. It has not been cleared by the Food and Drug Administration.
Disease
Chronic lymphocytic leukemia (CLL) Hematologic malignancies
Technology
Molecular
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| p53 Mutation Analysis/Sequence | 489103 | Body Site | 39111-0 |
| p53 Mutation Analysis/Sequence | 489077 | Results | 21739-8 |
| p53 Mutation Analysis/Sequence | 489087 | 80563-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 81352
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation