Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Rapid AML Panel

Rapid AML Panel: Labcorp test 484565

Labcorp test 484565, CPT 81120, 81121, 81245, 81246, 81310. Specimen: Whole blood or bone marrow. Turnaround: 3 - 5 days.

Rapid AML Panel is Labcorp test code 484565, billed with CPT 81120, 81121, 81245, 81246, 81310. Specimen: Whole blood or bone marrow. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code484565
CPT81120; 81121; 81245; 81246; 81310
LOINC49549-9, 72486-4, 72520-0
SpecimenWhole blood or bone marrow
Volume3-5 mL whole blood or 1-2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerLavender-top (EDTA) tube, green-top (sodium heparin) tube, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time3 - 5 days
Storage / transportRefrigerate. If specimen is to be stored prior to shipment, store at 2°C to 8°C.

Also known as: FLT3 ITD mutation; FLT3 TKD mutation; FLT3 D835 mutation; FLT3 ITD and D835 mutations; FLT3 ITD and TKD mutations; FLT3 Internal Tandem Duplication and Tyrosine Kinase Domain Mutation; NPM1 Mutation Analysis; IDH1/IDH2 Mutation Analysis; IDH1; IDH2; Isocitrate dehydrogenase 1 and 2; NADP+

Use

Mutations in the FLT3 gene are common mutations in acute myeloid leukemia (AML). This assay detects internal tandem duplication (ITD) mutations and mutations in the tyrosine kinase domain (TKD) of FLT3. Presence of these mutations in AML provide prognostic information and can aid in the determination of therapeutic regimen. FLT3 is a receptor tyrosine kinase (RTK) that dimerizes on binding its ligand, the cytokine FLT3 ligand (FL), which then undergoes autophosphorylation, and transduces signals downstream (STAT, AKT, ERK) that promote proliferation and survival. Activating mutations of FLT3 are common mutations found in AML. A particular form of FLT3 is mutated by duplicating coding…

Methodology

FLT3: Polymerase chain reaction (PCR); restriction enzyme digest; capillary electrophoresis NPM1: Polymerase chain reaction (PCR); capillary electrophoresis IDH1/2 SNaPshot: Multiplex PCR (primer extension-based method)

Collection instructions

Ship specimen at room temperature. Specimen should arrive in the laboratory within 48 hours of collection. Indicate date and time of collection on the request form.

Causes for rejection

Specimen does not meet collection criteria; frozen whole blood, marrow or cell pellet; leaking tube; clotted blood or marrow; grossly hemolyzed specimen or otherwise visibly degraded; contamination by another specimen; specimens containing suspicious foreign material

Special instructions

Please direct any questions regarding this test to customer service at 800-345-4363.

Limitations

The FLT3 PCR assay is capable of detecting a mutant cell population with a sensitivity of five mutant cells per 100. The NPM1 assay has a sensitivity to detect approximately 5% population of cells containing the 4 bp duplication or insertion in exon 11 in a background of nonmutant cells. This assay will not detect the mutation below the sensitivity of this assay or other NPM1 mutations. IDH1/2 SNaPshot vitro studies indicate that this assay has a sensitivity to detect approximately 5% mutated IDH1/2 in a background of nonmutant DNA. Mutations present at a level below the detection sensitivity or outside the analyzed region of the IDH1 and IDH2 genes will not be detected by this assay. This…

Disease

Acute myelocytic leukemia (AML) Hematologic malignancies Leukemia

Technology

Molecular

LOINC map

Result codeResult nameUnitsResult LOINC
Rapid AML Panel485019FLT3 D835 Result72520-0
Rapid AML Panel485015Method49549-9
Rapid AML Panel485017Director Review72486-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81120, 81121, 81245

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation