Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › α-Thalassemia Analysis

α-Thalassemia Analysis (Women's Health): Labcorp test 484278

Labcorp test 484278, CPT 81257. Specimen: Whole blood or PurFlock buccal swab kit. Turnaround: 9 - 12 days; in some cases, additional time may be required .

α-Thalassemia Analysis is Labcorp test code 484278, billed with CPT 81257. Specimen: Whole blood or PurFlock buccal swab kit. Turnaround time: 9 - 12 days; in some cases, additional time may be required . Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code484278 (Women's Health)
CPT81257
LOINC101387-9, 31208-2, 42349-1, 50397-9, 55234-9, 62385-0
SpecimenWhole blood or PurFlock buccal swab kit
Volume7 mL whole blood or PurFlock buccal swab kit
Minimum volume3 mL whole blood or PurFlock buccal swab kit
ContainerLavender-top (EDTA) tube or yellow-top (ACD-A) tube or PurFlock buccal swab kit
Turnaround time9 - 12 days; in some cases, additional time may be required for confirmatory or reflex tests
Storage / transportMaintain specimen at room temperature or refrigerate at 4°C. Do not freeze.

Also known as: Alpha-thal, HBA, alpha-globin, thalassemia

Test includes

This test includes the following genes: HBA1, HBA2 .

Use

This test is used for diagnostic or carrier testing for alpha-thalassemia.

Methodology

Analysis of the alpha-globin (HBA) gene cluster is performed by polymerase chain reaction (PCR) and multiplex ligation-dependent probe amplification (MLPA). Alpha-globin variants included in the analysis are the Constant Spring non-deletion variant and the following deletions: -alpha3.7, -alpha4.2, --alpha20.5, --SEA, --FIL, --THAI, --MED, and the HS-40 regulatory region.

Collection instructions

Standard phlebotomy

Stability

TemperaturePeriod
Room temperatureWhole blood: 14 days; buccal: 60 days
RefrigeratedWhole blood: 30 days

Causes for rejection

Frozen or hemolyzed specimen; quantity not sufficient for analysis; improper container; one buccal swab; wet buccal swab

Special instructions

To test fetal specimens, including cord blood, order α-Thalassemia, Fetal Analysis [484293].

Limitations

Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change with time if more information becomes available. False positive or false negative results may occur for reasons that include: rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism, mislabeled samples or erroneous representation of…

LOINC map

Result codeResult nameUnitsResult LOINC
484280Specimen Type31208-2
484281Indication42349-1
484282Result101387-9
484283Interpretation50397-9
484284Recommendations62385-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81257

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation