Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › GeneSeq® Immuno: Single Gene Analysis

GeneSeq® Immuno: Single Gene Analysis: Labcorp test 483991

Labcorp test 483991. Specimen: Whole blood or PurFlock buccal swab kit or Oragene Dx 500 saliva kit. Turnaround: 14 - 21 days; in some cases, additional time may be required.

GeneSeq® Immuno: Single Gene Analysis is Labcorp test code 483991. Specimen: Whole blood or PurFlock buccal swab kit or Oragene Dx 500 saliva kit. Turnaround time: 14 - 21 days; in some cases, additional time may be required. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code483991
CPTContact CPT coding department at 800-222-7566, ext. 6-8400.
LOINC—
SpecimenWhole blood or PurFlock buccal swab kit or Oragene Dx 500 saliva kit
Volume4 mL whole blood or PurFlock buccal swab kit or Oragene Dx 500 saliva kit
Minimum volume3 mL whole blood or PurFlock buccal swab kit or Oragene Dx 500 saliva kit
ContainerLavender-top (EDTA) tube or yellow-top (ACD-A) tube or PurFlock buccal swab kit or Oragene Dx 500 saliva kit
Turnaround time14 - 21 days; in some cases, additional time may be required for confirmatory or reflex tests
Storage / transportMaintain specimen at room temperature or refrigerate at 4°C. Do not freeze.

Test includes

This test includes all genes included in any GeneSeq® Immuno panel.

Use

Single gene analysis is available for all genes included in any GeneSeq® Immuno Panels.

Methodology

Next-generation sequencing to identify genetic variants, including small nucleotide variants (SNVs), insertions, deletions and copy number variants (CNVs)

Collection instructions

Standard phlebotomy; follow PurFlock buccal swab kit or Oragene Dx 500 saliva kit collection instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to collection.

Stability

TemperaturePeriod
Room temperatureWhole blood: 14 days; buccal swab: 60 days; saliva: 60 days
RefrigeratedWhole blood: 30 days; buccal swab: unstable; saliva: unstable

Causes for rejection

Frozen or hemolyzed specimen; quantity not sufficient for analysis; improper container

Special instructions

The specific gene(s) to be analyzed must be indicated on the test requisition form. Failure to indicate the gene(s) will result in testing delays. Variants of uncertain significance (VUS) will be reported. To test fetal specimens, including cord blood, order GeneSeq® Immuno: Single Gene, Fetal Analysis [484051]. Test orders must include an attestation that the provider has the patient's informed consent for genetic testing.

Limitations

Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations, including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change over time if more information becomes available. False positive or false negative results may occur for reasons that include rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism, mislabeled samples or erroneous representation of…

View this test on Labcorp's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation