Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Estrogen Receptor/Progesterone Receptor (ER/PR), Immunohistochemical, Paraffin Block

Estrogen Receptor/Progesterone Receptor (ER/PR), Immunohistochemical, Paraffin Block: Labcorp test 480277

Labcorp test 480277, CPT 88360. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tumor. Turnaround: 4 - 5 days.

Estrogen Receptor/Progesterone Receptor (ER/PR), Immunohistochemical, Paraffin Block is Labcorp test code 480277, billed with CPT 88360. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tumor. Turnaround time: 4 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code480277
CPT88360(x2)
LOINC14228-1, 14230-7
SpecimenFormalin-fixed, paraffin-embedded (FFPE) tumor
VolumeOne paraffin block or seven unstained, positively-charged tissue slides cut at 4 to 5 microns and dried for one hour at 60°C
ContainerParaffin block transport pouch or slide mailer
Turnaround time4 - 5 days
Storage / transportMaintain specimen at room temperature.

Also known as: ER/PR Assay; ER/PR, IHC, Paraffin Block

Test includes

Estrogen receptor analysis; progesterone receptor analysis

Use

Cancer prognosis: ER and PR positivity is a favorable prognostic factor in breast and endometrial carcinoma and meningioma. Response to endocrine therapy: Combined ER and PR positivity is associated with increased response to antiestrogen therapies.

Methodology

Immunohistochemistry (IHC). This is a semiquantitative measurement of ER/PR positive tumor nuclei in stained histologic tissue sections.

Collection instructions

Specimen should be fixed in 10% neutral-buffered formalin within one hour of collection. Optimum fixation time is six to 72 hours.

Special instructions

Please direct any questions regarding this test to oncology customer service at 800-345-4363.

Limitations

In the absence of internal positive control staining, a false-negative result cannot be excluded. The presence or absence of positive internal control staining is indicated on all negative reports. Use of fixatives other than 10% formalin may not yield equivalent or satisfactory results.

LOINC map

Result codeResult nameUnitsResult LOINC
Estrogen Receptor IHC%14228-1
Progesterone Rec. IHC%14230-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 88360

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation