Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › MET (SP44) IHC Non-Squamous NSCLC

MET (SP44) IHC Non-Squamous NSCLC: Labcorp test 412320

Labcorp test 412320, CPT 88360. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides.

MET (SP44) IHC Non-Squamous NSCLC is Labcorp test code 412320, billed with CPT 88360. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code412320
CPT88360
LOINC72486-4, 77202-0
SpecimenFormalin-fixed, paraffin-embedded (FFPE) tissue block or slides
VolumeOne paraffin block or five unstained, positively charged slides less than one month old
Minimum volumeThree unstained, positively charged slides
ContainerParaffin block; unstained, positive-charged slides
Storage / transportMaintain specimen at room temperature.

Use

The VENTANA MET (SP44) RxDx assay is a qualitative immunohistochemical assay using rabbit monoclonal anti-MET, clone SP44, intended for use in the assessment of MET protein in formalin-fixed paraffin embedded (FFPE) non-squamous non-small cell lung cancer (NSCLC) specimens by light microscopy. The VENTANA MET (SP44) RxDx assay is indicated as an aid in identifying non-squamous NSCLC patients who may be eligible for treatment with EMRELIS™ (telisotuzumab vedotin-tllv).

Methodology

Immunohistochemistry

Collection instructions

Tissue should be fixed in 10% neutral-buffered formalin (NBF) for six to 72 hours. Embed in paraffin. Slides should be no more than one month old.

Causes for rejection

Insufficient tumor; tumor other than non-squamous non-small-cell lung cancer; slides sectioned more than one month prior to test request

Special instructions

Testing will be delayed if the pathology report is not received.

Limitations

Tissue staining is dependent on the handling and processing of the tissue before staining. Improper fixation, freezing, thawing, washing, drying, heating, sectioning or contamination with other tissues or fluids may produce artifacts or false negative results. Inconsistent results may arise from variations in fixation and embedding methods. The recommended fixative is 10% NBF. Fix samples in formalin for six to 72 hours. Zinc formalin is also acceptable for fixative time of six to 72 hours. Samples fixed in formalin and zinc formalin for fixation times less than six hours have demonstrated a loss of specific MET immunoreactivity and can lead to a false negative result. Fixatives such as…

LOINC map

Result codeResult nameUnitsResult LOINC
MET (SP44) IHC NONSQUAM-NSCLC412323Comment77202-0
MET (SP44) IHC NONSQUAM-NSCLC412325Review72486-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 88360

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation