Urinalysis, Complete With Microscopic Examination With Reflex to Urine Culture, Routine: Labcorp test 377036
Labcorp test 377036, CPT 81001. Specimen: Urine (random). Turnaround: 2 - 5 days.
Test includes
Reflex to routine urine culture (equivalent to test 008847 ). Specimen will reflex to a routine urine culture if any one of the following criteria is present: 1. Positive nitrite on reagent strip 2. Positive leukocyte esterase on reagent strip 3. >5 WBC/hpf on urinalysis microscopic examination 4. ≥Moderate bacteria on urinalysis microscopic examination
Use
Detect abnormalities of urine; diagnose and manage renal diseases, urinary tract infection, urinary tract neoplasms, systemic diseases, and inflammatory or neoplastic diseases adjacent to the urinary tract.
Methodology
Reagent strip with light microscopy
Collection instructions
A voided specimen is usually suitable. If the specimen is likely to be contaminated, a clean-catch midstream specimen is desirable.
Causes for rejection
Urinalysis ONLY: quantity not sufficient for analysis; improper labeling; tubes with boric acid or tartaric acid (e.g., BD gray-top C&S tube); Labcorp red-top C&S tube; Boricon, Bortiex, or Boricult yellow-top C&S tubes, urine transport tube with Triclosan; specimen received in Vacutainer® red/yellow urine transport tube more than 72 hours old; specimen received in urine cup stored at room temperature greater than 2 hours old; specimen received in urine cup refrigerated more than 48 hours old; frozen specimens; Vacutainer® red/yellow urine transport tube less than 3 mL or greater than 9 mL Culture ONLY: quantity not sufficient for analysis; improper labeling; specimen received in urine cup stored at room temperature greater than 2 hours old; specimen received in urine cup refrigerated more than 48 hours old, frozen specimens
Limitations
Insufficient volume may limit the extent of procedures performed. Metabolites of Pyridium® may interfere with the dipstick reactions by producing color interference. High vitamin C intake may cause an underestimate of glucosuria, or a false-negative nitrite test. Survival of WBCs is decreased by low osmolality, alkalinity, and lack of refrigeration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 013060 | Specific Gravity | 5811-5 | |
| 013078 | pH | 5803-2 | |
| 013045 | Urine-Color | 5778-6 | |
| 013052 | Appearance | 5767-9 | |
| 013185 | WBC Esterase | 5799-2 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 81001
- Pregnancy, Initial Screening Profile
- Pregnancy, Initial Screening Profile With HBV Triple Panel
- Pregnancy, Initial Screening Profile With HBV Triple Panel, VZV Immunity and QuantiFERON®-TB Gold Plus
- Urinalysis with Microscopic
- Urinalysis, Complete With Microscopic Examination
- Pregnancy, Initial Screening Profile
- Urinalysis, Complete With Microscopic Examination
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.