Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Gynecologic Pap Test−Age-based Guideline for Cervical Cancer Screening (Cobas® method) Plus Chlamydia/Gonococcus/Trichomonas

Gynecologic Pap Test−Age-based Guideline for Cervical Cancer Screening (Cobas® method) Plus Chlamydia/Gonococcus/Trichomonas: Labcorp test 193100

Labcorp test 193100. Specimen: Cervical cells in ThinPrep® vial. Turnaround: 3 - 6 days.

Gynecologic Pap Test−Age-based Guideline for Cervical Cancer Screening (Cobas® method) Plus Chlamydia/Gonococcus/Trichomonas is Labcorp test code 193100. Specimen: Cervical cells in ThinPrep® vial. Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code193100
CPTCall client services.
LOINC—
SpecimenCervical cells in ThinPrep® vial
VolumeThinPrep® vial
Minimum volumeA minimum volume cannot be determined for the ThinPrep® vial because it varies depending on the cellularity of the specimen.
ContainerThinPrep® vial
Turnaround time3 - 6 days
Storage / transportMaintain liquid-based cytology specimens at room temperature. Pap processing must be performed within 21 days of collection. ThinPrep® vial may be stored for six months after the date of collection prior to performing the Cobas® HPV test. ThinPrep® specimens should not be frozen. Liquid-based cytology specimens must be tested within seven days for Chlamydia/Gonococcus/Trichomonas.

Use

Diagnose primary or metastatic neoplasm. Detect Chlamydia trachomatis , Neisseria gonorrhoeae, and Trichomonas vaginalis. High-risk HPV is used for types 16 and 18 and a combined result for types 31,33,35,39,45,51,52,56,58,59,66, and 68, without differentiation of the individual type. This information, together with the physician's assessment of cytology history, other risk factors, and professional guidelines, may be used to guide patient management. The results of this test are not intended to prevent women from proceeding to colposcopy.

Methodology

Image-guided liquid-based Pap test; nucleic acid amplification (NAA). LabCorp protocol is based on ACOG guidelines.

Collection instructions

Brush/spatula technique: Insert the brush into the endocervical canal until only the bottom-most fibers are exposed. Slowly rotate the brush ¼ to ½ turn in one direction. Do not over-rotate the brush. Then, rotate the brush in the PreservCyt® solution 10 times while pushing against the wall of the ThinPrep® vial. Swirl the brush vigorously to release additional material. Discard the brush. Obtain an adequate sample from the ectocervix using a plastic spatula. Swirl vigorously in the ThinPrep® vial 10 times and discard the spatula. Tighten the cap on the ThinPrep® container so that the torque line on the cap passes the torque line on the vial.

Patient preparation

Patient should avoid douches 48 to 72 hours prior to examination. Specimen should not be collected during or shortly after menstrual period.

Causes for rejection

Improper collection; inadequate specimen; improper labeling; frozen specimen; specimen leaked in transit; quantity not sufficient for analysis; name discrepancies; specimen submitted on male patients; For Pap: liquid-based cytology specimen more than 21 days old. For HPV: specimen more than six months old in ThinPrep® vial; excessively bloody specimens. For Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis: liquid-based cytology specimen more than seven days old.

Special instructions

Include date of birth, Social Security number (or other identification number), previous malignancy, drug therapy, radiation therapy, last menstrual period (LMP), postmenopausal patient (PMP), surgery (including surgical biopsies), exogenous hormones, abnormal vaginal bleeding, abnormal Pap results, IUD, and all other pertinent clinical information on the cytology test request form. Note: In accordance with criteria established by CLIA, Pap smears will be referred for pathologist review if laboratory personnel suspect: • Reactive or reparative cellular changes • Atypical squamous or glandular cells of undetermined significance • Cells in the premalignant or malignant category In these cases, LabCorp will charge for the associated service. (Slides that are routinely reviewed by a pathologist for quality control purposes are not included.)

Limitations

Failure to obtain adequate ectocervical, endocervical, or vaginal cell population is suboptimal for evaluation. Excessive use of lubricating jelly on the vaginal speculum will interfere with cytologic examination and may lead to unsatisfactory Pap results. The use of the liquid-based cytology specimen for multiple tests may limit the volume available for Pap reprocessing or HPV testing. A negative result does not exclude the possibility of an HPV infection, since very low levels of infection or sampling error may produce a false-negative result. This test detects only the 14 most common high-risk HPV types. Testing for Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis…

View this test on Labcorp's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.