Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Herpes Simplex Virus (HSV) Types 1 and 2, NAA

Herpes Simplex Virus (HSV) Types 1 and 2, NAA (Women's Health): Labcorp test 188056

Labcorp test 188056, CPT 87529. Specimen: Vesicular fluid, ulcerated lesions, vaginal, or endocervical cells collected by one of the methods described below. Turnaround: 2 - 4 days.

Herpes Simplex Virus (HSV) Types 1 and 2, NAA is Labcorp test code 188056, billed with CPT 87529. Specimen: Vesicular fluid, ulcerated lesions, vaginal, or endocervical cells collected by one of the methods described below. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code188056 (Women's Health)
CPT87529(x2)
LOINC16131-5
SpecimenVesicular fluid, ulcerated lesions, vaginal, or endocervical cells collected by one of the methods described below
VolumeOne swab or entire liquid cytology vial
Minimum volumeOne swab or entire liquid cytology vial
ContainerAptima® unisex or Aptima® vaginal swab transport or swab in Universal or Viral Transport Media (UTM/VTM) or ThinPrep® liquid cytology vial
Turnaround time2 - 4 days
Storage / transportMaintain specimen at ambient or refrigerated temperature.

Use

This test is used to detect and type active HSV shedding.

Methodology

Nucleic acid amplification (NAA)

Collection instructions

Lesion/vesicle swab: Unroof or scrape the lesion with an Aptima® swab (for Aptima® collections) or with a synthetic swab for UTM/VTM collections. Vaginal swab: Collect vaginal fluid sample using the Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Endocervical swab in Aptima®: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shafted swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shafted swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline using care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. ThinPrep® Vial − Broom or Brush/Spatula Broom-like collection technique: Obtain a sample from the cervix using a broom-like device by inserting the brush portion into the cervical os and then rotating the brush five times. Rinse the collection device in the PreservCyt® solution by pushing the brush into the bottom of the vial 10 times, forcing the bristles to bend apart to release the cervical material. As a final step, twirl the brush between the thumb and forefinger vigorously to release additional cellular material. Discard the collection device. Tighten the cap on the ThinPrep® vial so that the torque line on the cap passes the torque line on the vial. Brush/spatula technique: Insert the brush into the endocervical canal until only the bottommost fibers are exposed. Slowly rotate the brush ¼ to ½ turn in one direction. Do not over-rotate the brush. Then, rotate the brush in the PreservCyt® solution 10 times while pushing against the wall of the ThinPrep® vial. Swirl the brush vigorously to release additional material. Discard the brush. Obtain an adequate sample from the ectocervix using a plastic spatula. Swirl vigorously in the ThinPrep® vial 10 times and discard the spatula. Tighten the cap on the ThinPrep® container so that the torque line on the cap passes the torque line on the vial.

Causes for rejection

Urine specimen; specimen transported under inappropriate conditions; bacterial swabs; unlabeled specimen or discrepancy between specimen label and test request form; Aptima® COMBO 2 (AC2) swab specimen transport tube with two swabs or swab not supplied by Hologic or no swab; ProbeTec™ swabs; female urethral swab; SurePath™ vial; Aptima® swab transports >7 days from collection; specimens submitted in non-FDA cleared UTM or VTM

Limitations

This test is intended for use as an aid in the diagnosis of herpes simplex virus (HSV) infections with active viral shedding; it also differentiates HSV-1 from HSV-2. Negative HSV NAA results indicate lack of viral shedding but do not confirm absence of previous infection. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
HSV NAA188058HSV 2 NAA16131-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87529

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation