Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Influenza A and B, Direct Immunoassay

Influenza A and B, Direct Immunoassay: Labcorp test 186064

Labcorp test 186064, CPT 87804. Specimen: Nasopharyngeal (NP) swab in viral transport medium or NP wash or aspirate. Turnaround: 1 - 2 days.

Influenza A and B, Direct Immunoassay is Labcorp test code 186064, billed with CPT 87804. Specimen: Nasopharyngeal (NP) swab in viral transport medium or NP wash or aspirate. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code186064
CPT87804(x2)
LOINC33535-6, 46082-4, 46083-2, 77202-0
SpecimenNasopharyngeal (NP) swab in viral transport medium or NP wash or aspirate
Volume2 to 3 mL NP wash, 0.5 mL NP aspirate dispersed in at least 2 to 3 mL transport medium or saline, or swab
Minimum volume2 mL NP wash, 0.5 mL NP aspirate dispersed in at least 2 to 3 mL transport medium or saline
ContainerViral, Chlamydia , or Mycoplasma culture transport provided by LabCorp, or other appropriate transport medium; sterile leakproof container
Turnaround time1 - 2 days
Storage / transportRefrigerate.

Also known as: Flu A and B

Use

Confirm the diagnosis of influenza type A or type B infection. This is a differentiated test and, therefore, will distinguish influenza type A from influenza type B.

Methodology

Direct immunoassay (IA)

Causes for rejection

Bacterial swab specimen; specimen received in grossly leaking transport container; dry specimen; specimen submitted in fixative or additive; specimen received in expired transport media or incorrect transport device; inappropriate specimen transport conditions; specimen received after prolonged delay in transport (usually more than 72 hours); specimen stored or transported at room temperature; wooden shaft swab in transport device; unlabeled specimen or name discrepancy between specimen and request label

Reference range

Negative

Special instructions

Submit one specimen per test requested. Specify the exact specimen source/origin (eg, nasopharynx). Indicate a specific test number on the request form. Check expiration date of transport; do not use expired devices.

LOINC map

Result codeResult nameUnitsResult LOINC
186065Influenza A Ag, EIA46082-4
186066Influenza B Ag, EIA46083-2
186067Comment77202-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87804

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation