Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Acid-fast Organism Identification by PCR, MALDI-TOF and/or Sequencing

Acid-fast Organism Identification by PCR, MALDI-TOF and/or Sequencing: Labcorp test 183158

Labcorp test 183158, CPT 87150. Specimen: Isolated acid-fast bacillus (AFB) on agar or egg-based media; broth system positive for AFB (ensure it is not contaminat. Turnaround: 15 - 24 days.

Acid-fast Organism Identification by PCR, MALDI-TOF and/or Sequencing is Labcorp test code 183158, billed with CPT 87150. Specimen: Isolated acid-fast bacillus (AFB) on agar or egg-based media; broth system positive for AFB (ensure it is not contaminated with non acid-fas. Turnaround time: 15 - 24 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code183158
CPT87150
LOINC71719-9
SpecimenIsolated acid-fast bacillus (AFB) on agar or egg-based media; broth system positive for AFB (ensure it is not contaminated with non acid-fast bacteria)
VolumeEntire container
ContainerScrew cap agar-slant tube; bacterial swab transport inoculated with isolated colonies from a pure culture; liquid-based broth tube from BD, bioMerieux or VersaTREK (slant, swab or liquid-based broth must be packed as an etiologic agent)
Turnaround time15 - 24 days
Storage / transportMaintain specimen at room temperature.

Also known as: AFB Culture, Identification

Use

This test is used to identify acid-fast bacteria referred from another laboratory that has performed the culture of the clinical sample. Note: PCR testing for identification of M. avium complex and M. tuberculosis complex will be performed on VersaTREK liquid-based broth submissions only. Organisms not identified by PCR will have additional charges for identification by MALDI-TOF and/or nucleic acid sequencing.

Methodology

Identification by PCR, MALDI-TOF and/or nucleic acid sequencing

Causes for rejection

Specimen received leaking or in broken transport tube or vial; unlabeled or name discrepancy between specimen and request label; primary clinical specimen received

Special instructions

If reflex test is performed, additional charges/CPT code(s) may apply.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
AFB Identification183164M avium complex71719-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87150

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation