Sound Lab Consultants › National Lab Test Directory › Labcorp › Group A Streptococcus Detection, NAA

Group A Streptococcus Detection, NAA: Labcorp test 180800

Labcorp test 180800, CPT 87651. Specimen: Swab of posterior oropharynx, tonsils, or other inflamed area. Turnaround: 1 - 2 days.

Group A Streptococcus Detection, NAA is Labcorp test code 180800, billed with CPT 87651. Specimen: Swab of posterior oropharynx, tonsils, or other inflamed area. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code180800
CPT87651
LOINC60489-2
SpecimenSwab of posterior oropharynx, tonsils, or other inflamed area
VolumeSingle flocked swab in liquid Amies (ESwab)
ContainerESwab only (Copan Liquid Amies Elution Swab transport, PeopleSoft No. 130839)
Turnaround time1 - 2 days
Storage / transportThroat swabs in liquid Amies (ESwab) are transported to the laboratory at room temperature within 48 hours after specimen collection, or they can be refrigerated for up to six days.

Use

Detection of Group A Streptococcus in throat swab specimens from patients with signs and symptoms of pharyngitis

Methodology

Real-time polymerase chain reaction (PCR)

Collection instructions

Using a flocked swab and tongue depressor blade, roll the swab over the tonsillar area and posterior oropharynx, including any ulceration, exudate, lesion, or any area of apparent inflammation.

Stability

TemperaturePeriod
Room temperature48 hours (stability provided by manufacturer or literature reference)
Refrigerated6 days (stability provided by manufacturer or literature reference)
FrozenN/A (stability provided by manufacturer or literature reference)

Patient preparation

Do not collect throat swab specimens immediately after patients have used antiseptic mouthwash.

Causes for rejection

Improper labeling; transport device other than an ESwab; specimen received at room temperature after 48 hours or refrigerated after six days; source other than throat

Reference range

Negative

Limitations

A negative test result does not exclude the possibility of infection because the test result may be affected by improper specimen collection or because the number of organisms in the sample is below the limit of detection of the test.

LOINC map

Result codeResult nameUnitsResult LOINC
180799Strep Gp A Detection, NAA60489-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87651

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation