Labcorp test 180764, CPT 87338. Specimen: Stool. Turnaround: 2 - 4 days.

Helicobacter pylori Stool Antigen is Labcorp test code 180764, billed with CPT 87338. Specimen: Stool. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code180764
CPT87338
LOINC17780-8
SpecimenStool
Volume2 g (thumbnail size portion of stool), 2 mL liquid stool
Minimum volume1 g stool, 1 mL liquid stool
ContainerSterile screw-cap vial (Para-Pak® white clean vial)
Turnaround time2 - 4 days
Storage / transportSpecimen should be kept refrigerated after collection and transported refrigerated to the laboratory within 72 hours. If a longer period is required, or if the specimen is being sent to another lab for testing, the specimen should be frozen at -70°C.

Also known as: Campylobacter pylori; Campylobacter From Stomach; H pylori Stool Antigen; Culture, Helicobacter pylori

Test includes

Immunoassay for Helicobacter pylori

Use

This test is used to establish the presence and possible etiologic role of Helicobacter pylori in cases of chronic gastric ulcer, gastritis, duodenal ulcer, dyspepsia, etc.

Methodology

Immunoassay

Stability

TemperaturePeriod
Room temperatureN/A
Refrigerated72 hours
Frozen-70°C: 4 weeks

Causes for rejection

Inappropriate specimen transport conditions (e.g., room temperature) or device; unlabeled specimen or name discrepancy between specimen and request label; specimen received after prolonged delay (usually more than 72 hours); leaking specimen; specimen received in inappropriate container (denture cup, “Cool Whip” container, margarine container, or similar container)

Contraindications

Antimicrobials, proton pump inhibitors, and bismuth preparations are known to suppress H. pylori , and ingestion of these prior to H. pylori testing may give a false-negative result. If a negative result is obtained for a patient ingesting these compounds within two weeks prior to performing the stool antigen test, it may be a false-negative result and the test should be repeated on a new specimen obtained two weeks after discontinuing treatment. A positive result for a patient ingesting these compounds within two weeks prior to performing the stool antigen test should be considered accurate.

LOINC map

Result codeResult nameUnitsResult LOINC
180764H. pylori Stool Ag, EIA17780-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87338

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation