Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › HLA A,B,C Profile (High Resolution)

HLA A,B,C Profile (High Resolution): Labcorp test 176088

Labcorp test 176088, CPT 81379. Specimen: Whole blood or buccal swabs. Turnaround: 3 - 7 days.

HLA A,B,C Profile (High Resolution) is Labcorp test code 176088, billed with CPT 81379. Specimen: Whole blood or buccal swabs. Turnaround time: 3 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code176088
CPT81379
LOINC13298-5, 42664-3, 57291-7, 96615-0
SpecimenWhole blood or buccal swabs
Volume7 mL whole blood or four buccal swabs
Minimum volume3 mL whole blood or four buccal swabs
ContainerLavender-top (EDTA) tube or four buccal swabs in a sealed envelope (buccal swab kit). When submitting buccal swabs, please use a buccal swab kit provided by LabCorp. To obtain the buccal swab kit, please telephone 800-533-1037.
Turnaround time3 - 7 days
Storage / transportMaintain specimen at room temperature; protect from extreme heat or cold. Do not freeze.

Also known as: HLA, Transplant

Use

HLA antigens may be correlated with certain disease states or other clinical conditions. Indicate in clinical information which antigen(s) is of interest. Also used for screening of transplant candidates and potential donors, transfusion of specifically compatible blood products, among others. High resolution HLA typing is preferred for matching of bone marrow transplant donors and recipients. Other clinical indications may require high resolution typing to rule out alternative allele combinations. High resolution typing for HLA class I will meet the following criteria: All ambiguities within exons 2 and 3, which defines the antigen recognition site, and exon 4, will be resolved. Those…

Methodology

HLA results are obtained using Next Generation Sequencing (NGS). Supplemental procedures based on Sanger sequence based typing (SBT) may be used as needed to obtain the required resolution.

Causes for rejection

Hemolyzed specimen; clotted specimen; wrong specimen container

Special instructions

If you have questions, please call 800-533-1037 (HLA customer service) for assistance in selecting the proper HLA test for the patient.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
019414HLA-A13298-5
019415HLA-A13298-5
167339HLA-B57291-7
167341HLA-B57291-7
019430HLA-C42664-3
019431HLA-C42664-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81379

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation