HLA Class I Antibody Identification: Labcorp test 168058
Labcorp test 168058, CPT 86832. Specimen: Serum. Turnaround: 2 - 5 days.
HLA Class I Antibody Identification is Labcorp test code 168058, billed with CPT 86832. Specimen: Serum. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs).
Test code168058
CPT86832
LOINC46994-0
SpecimenSerum
Volume7 mL
Minimum volume3 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 5 days
Storage / transportMaintain specimen at room temperature. Protect from extreme heat or cold. Serum may be frozen .
Also known as: HLA Class 1 Antibody; White Cell Antibody
Use
Solid organ transplantation
Methodology
Solid phase (Luminex)
Stability
| Temperature | Period |
|---|
| Room temperature | 2 days |
| Refrigerated | 1 month |
| Frozen | 2 years |
Causes for rejection
Highly lipemic or hemolyzed specimen
Special instructions
Collect specimen prior to dialysis. Do not collect if patient has received antithymocyte globulin, OKT3, or alemtuzumab (Campath®) recently. These drugs may cause false-positive results.
Limitations
Detects antibodies of the IgG isotype and not IgM antibodies, which are usually indicative of autoantibodies.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| HLA Ab HD 1 | % CPRA | | 46994-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86832
- HLA Antibody Specificity
Michigan Medicine Laboratories (MLabs)Test code HLASCPT 86832, 868335 mL serumTAT STAT: 48 hours; Routine: 5 days
- HLA Class I Antibody C1q Binding Assay
LabcorpTest code 176056CPT 86832SerumTAT 2 - 5 days
- HLA Donor Specific Antibody (DSA)
Michigan Medicine Laboratories (MLabs)Test code HLDSACPT 86832, 86833Full tube, Red Top/SSTTAT 5 days
- HLA Single Antigen - C1q Binding Antibody Screen (UCLA)
Michigan Medicine Laboratories (MLabs)Test code C1QPN reflexing to C1QA1 or C1QA2CPT 86832, 868335 mL serumTAT 2 - 4 days
- HLA Solid Organ Transplant, New Patient
Michigan Medicine Laboratories (MLabs)Test code HLLRD, HLASCPT 81370, 81376, 86832, 86833HLLRD: Full tubes, 2- Yellow top (ACD) solution A tubeTAT 5 days
- HLA Donor Specific Antibody
Michigan Medicine Laboratories (MLabs)Test code HLASHla Donor Specific AntibodyCPT 86832, 868335 mL serumTAT STAT: 48 hours; Routine: 5 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.