HLA Class I Antibody and HLA Class II Antibody Screen: Labcorp test 168050
Labcorp test 168050, CPT 86828. Specimen: Serum. Turnaround: 3 - 5 days.
Also known as: HLA Antibody, PRA; HLA Class 1/2 Antibody, White Cell Antibody
Use
Solid organ transplantation
Methodology
Solid phase (Luminex)
Collection instructions
To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .
Stability
| Temperature | Period |
|---|---|
| Room temperature | 2 days |
| Refrigerated | 1 month |
| Frozen | 2 years |
Causes for rejection
Highly lipemic or hemolyzed specimen
Special instructions
Collect specimen prior to dialysis. Do not collect if patient has received antithymocyte globulin, OKT3, or alemtuzumab (Campath®) recently. These drugs may cause false-positive results.
Limitations
This test provides limited information as to the HLA specificities of the antibodies. Detects antibodies of the IgG isotype and not IgM antibodies, which are usually indicative of autoantibodies.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| HLA Class 1,2 Antibody Screen | 167105 | Class II Ab Screen | 50968-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86828
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.