Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Auto-Crossmatch

Auto-Crossmatch: Labcorp test 167145

Labcorp test 167145, CPT 86825. Specimen: Donor sample: Whole blood; Recipient sample: Serum. Turnaround: 2 - 5 days.

Auto-Crossmatch is Labcorp test code 167145, billed with CPT 86825. Specimen: Donor sample: Whole blood; Recipient sample: Serum. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code167145
CPT86825
LOINC48390-9
SpecimenDonor sample: Whole blood; Recipient sample: Serum
VolumeBlood sample: 12 mL; Serum sample: 2 mL
Minimum volumeBlood sample: 8 mL; Serum sample: 2 mL
ContainerDonor sample: Yellow-top (ACD) tube (solution A or B). Recipient sample: Red-top tube or gel-barrier tube
Turnaround time2 - 5 days
Storage / transportMaintain whole blood and serum at room temperature. Specimens should be analyzed within 72 hours of collection. Serum may be stored at 4°C for one week or at -20°C indefinitely.

Also known as: Flow Crossmatch; HLA Crossmatch; T-Cell and B-Cell Crossmatch

Use

Detection of the presence of autoantibodies (HLA) in a solid organ recipient. T- and B-cell crossmatch detects the presence of anti-Class I/Class II HLA antibodies in the patient.

Methodology

Presence of antibody bound to human lymphocytes detected by immunofluorescence and flow cytometry

Patient preparation

None

Causes for rejection

EDTA or heparin tube; hemolysis; clotted specimen; donor samples exceeding 72 hours

Special instructions

To schedule this test, you must telephone 800-533-1037, HLA customer service.

Limitations

Although the primary antibodies that are detected by this assay are to HLA, other non-HLA specific antibodies could cause positive T- and/or B-cell crossmatch. This test only demonstrates antibodies that recognize donor antigens and cannot distinguish clinical relevant antibodies (eg, complement binding ability) from nonclinical antibodies. This assay only detects the presence of IgG antidonor antibodies and does not detect IgM or other immunoglobulin subclasses. This test was developed, and its performance characteristics determined, by LabCorp. It has not been cleared or approved by the US Food and Drug Administration (FDA).

LOINC map

Result codeResult nameUnitsResult LOINC
Auto-Crossmatch by Flow167187AutoCrossmatch B-Cell(AUBCELL)48390-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86825

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation