SARS-CoV-2 Semi-Quantitative Total Antibody, Spike: Labcorp test 164090
Labcorp test 164090, CPT 86769. Specimen: Serum or plasma. Turnaround: 1 - 3 days.
Also known as: SARS-CoV-2 Antibody Titer
Use
Qualitative and semi-quantitative detection of antibodies to SARS-CoV-2 spike protein receptor binding domain (RBD). Aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection. At this time it is unknown how long antibodies persist following infection and if the presence of antibodies confers protective immunity. The performance of this test has not been established in individuals that have received a COVID-19 vaccine. The clinical significance of a positive or negative antibody result following COVID-19 vaccination has not been established and the result from this test should not be interpreted as an indication or degree of…
Methodology
Electrochemiluminescence Immunoassay (ECLIA)
Stability
| Temperature | Period |
|---|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 28 days (stability provided by manufacturer or literature reference) |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Gross hemolysis; visible microbial contamination
Special instructions
On May 19, 2021, the FDA issued a safety communication reiterating that "antibody testing should not be used to evaluate a person's level of immunity or protection from COVID-19 at any time, and especially after the person received a COVID-19 vaccination." Visit http://www.fda.gov/medical-devices/safety-communications/antibody-testing-not-currently-recommended-assess-immunity-after-covid-19-vaccination-fda-safety for more information.
Limitations
This test should not be used to diagnose or exclude acute SARS-CoV-2 infection. The results should always be assessed in conjunction with patient's medical history, clinical presentation, and other findings. A negative test result does not rule out the possibility of an infection with SARS-CoV-2. Serum or plasma samples from the very early (pre-seroconversion) phase can yield negative findings. Therefore, this test cannot be used to diagnose an acute infection. It has also been reported that certain patients with confirmed infection do not develop SARS-CoV-2 antibodies. Furthermore, waning of antibody titers has been reported in some individuals within a range of months after infection, a…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 164091 | SARS-CoV-2 Semi-Quant Spike Ab | U/mL | 94769-7 |
| 164092 | SARS-CoV-2 Spike Ab Interp | 94661-6 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86769
- COVID-19 IgG, Qualitative by CIA
- SARS-CoV-2 (COVID-19), Total Antibodies, Nucleocapsid, Qualitative
- SARS-CoV-2 Antibodies, Nucleocapsid
- SARS-CoV-2 Antibody Profile, Nucleocapsid and Spike
- SARS-CoV-2 Semi-Quantitative IgG Antibody, Spike
- Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), Nucleocapsid, Total Antibody, Serum
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation