Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Antineutrophil Cytoplasmic Antibodies (ANCA)

Antineutrophil Cytoplasmic Antibodies (ANCA): Labcorp test 162388

Labcorp test 162388, CPT 86037. Specimen: Serum. Turnaround: 3 - 5 days.

Antineutrophil Cytoplasmic Antibodies (ANCA) is Labcorp test code 162388, billed with CPT 86037. Specimen: Serum. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code162388
CPT86037(x3)
LOINC14277-8, 14278-6, 49503-6
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 5 days
Storage / transportRoom temperature

Test includes

Antineutrophil cytoplasmic autoantibodies exhibiting pANCA or cANCA patterns are detected using indirect immunofluorescent antibody (IFA) techniques with a substrate of ethanol-fixed human neutrophils. Positive patient sera with perinuclear or nuclear patterns are repeated using a formalin-fixed substrate in order to differentiate the presence of true pANCA antibodies from possible interference with antinuclear antibodies (ANA).

Use

Antineutrophil cytoplasmic autoantibodies (ANCA) are a serological marker associated with vasculitis and glomerulonephritis. Specifically, ANCA have been found (at frequencies ranging from 70% to 90%) in patients with active Wegener granulomatosis, microscopic polyarteritis nodosa, and idiopathic crescentic glomerulonephritis (with manifestations ranging from kidney-limited disease to extrarenal systemic disease, including pulmonary-renal syndromes). Glomerular lesions in patients with ANCA-associated systemic vasculitis or renal-limited disease are virtually identical. Normal controls are negative for ANCA and <10% of patients with other renal diseases are positive. ANCA may be directly…

Methodology

Indirect fluorescent antibody (IFA)

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross hemolysis; lipemia; bacterial contamination

Reference range

Negative: <1:20

LOINC map

Result codeResult nameUnitsResult LOINC
Cytoplasmic (C-ANCA)titer14277-8
Perinuclear (P-ANCA)titer14278-6
Atypical pANCAtiter49503-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86037

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation