Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Heparin-dependent Platelet Antibody (Serotonin Release Assay)

Heparin-dependent Platelet Antibody (Serotonin Release Assay): Labcorp test 150018

Labcorp test 150018, CPT 82542. Specimen: Serum, frozen. Turnaround: 3 - 7 days.

Heparin-dependent Platelet Antibody (Serotonin Release Assay) is Labcorp test code 150018, billed with CPT 82542. Specimen: Serum, frozen. Turnaround time: 3 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code150018
CPT82542
LOINC50727-7, 77728-4
SpecimenSerum, frozen
Volume1 mL
Minimum volume0.5 mL
ContainerGel-barrier or red top tube
Turnaround time3 - 7 days
Storage / transportFreeze.

Also known as: Functional HIT Assay

Use

Confirmatory assay used in the evaluation of heparin-induced thrombocytopenia (HIT)

Methodology

The SRA employs washed donor platelets and detects their activation by measuring the release of endogenous serotonin induced by addition of patient serum. The serotonin levels are measured by a highly sensitive liquid chromatography/tandem mass spectroscopy method. Therapeutic levels of heparin included in the assay mix allow for the formation of PF4/heparin complexes on the donor platelet surface to provide an antigen target for the HIT antibodies. The specificity of the assay is increased by assessing the inhibition of platelet activation by adding heparin in excess, thus proving the heparin dependency of the serotonin release.

Collection instructions

Transfer serum to a plastic transport tube. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Causes for rejection

Room temperature specimen received; grossly hemolyzed, icteric, and lipemic samples

Limitations

The diagnosis of heparin-induced thrombocytopenia should not be based entirely on the results of the Heparin-dependent Platelet Antibody assay and should take into account the results of the immunologic HIT assay, presence and timing of thrombocytopenia in relation to heparin administration, the presence of thrombosis or other HIT-related sequelae, as well as determination of other causes of thrombosis. This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
SRA, Low Dose Heparin%77728-4
SRA, High Dose Heparin%50727-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82542

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation