Sound Lab Consultants › National Lab Test Directory › Labcorp › Phospholipase A2 Receptor Autoantibodies, IgG

Phospholipase A2 Receptor Autoantibodies, IgG: Labcorp test 141330

Labcorp test 141330, CPT 83516. Specimen: Serum. Turnaround: 2 - 8 days.

Phospholipase A2 Receptor Autoantibodies, IgG is Labcorp test code 141330, billed with CPT 83516. Specimen: Serum. Turnaround time: 2 - 8 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code141330
CPT83516
LOINC73737-9
SpecimenSerum
Volume0.5 mL
Minimum volume0.2 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 8 days
Storage / transportRoom temperature

Also known as: Antibodies to the M-type Phospholipase A2 Receptor

Use

The anti-PLA2R ELISA (IgG) test kit is intended for the qualitative or semiquantitative determination of IgG class autoantibodies against phospholipase A2 receptor (PLA2R) in human serum. It is used as an aid in the diagnosis of primary membranous glomerulonephritis (pMGN), in conjunction with other laboratory and clinical findings.

Methodology

Enzyme-linked immunosorbent assay (ELISA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Limitations

The test is not a standalone test but an adjunct to other clinical information. A diagnosis of membranous nephropathy (MN) should not be made on a single test result. The clinical symptoms, results on physical examination, and laboratory tests (eg, serological tests), when appropriate, should always be taken into account when considering the diagnosis of primary versus secondary MN. Absence of circulating PLA2R autoantibodies does not rule out a diagnosis of PLA2R-related membranous nephropathy. Clinical evidence must not be overruled in favor of a numerical value. The assay has not been demonstrated to be effective for monitoring the stage of disease or its response to…

LOINC map

Result codeResult nameUnitsResult LOINC
141331Anti-PLA2RRU/mL73737-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83516

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation