Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Intact N-Terminal Propeptide of Type 1 Procollagen

Intact N-Terminal Propeptide of Type 1 Procollagen: Labcorp test 140850

Labcorp test 140850, CPT 82523. Specimen: Serum. Turnaround: 3 - 5 days.

Intact N-Terminal Propeptide of Type 1 Procollagen is Labcorp test code 140850, billed with CPT 82523. Specimen: Serum. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140850
CPT82523
LOINC47255-5
SpecimenSerum
Volume0.5 mL
Minimum volume0.4 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 5 days
Storage / transportMaintain specimen at room temperature.

Also known as: PINP

Use

This test is used for measurement of Intact N-Terminal Propeptide of Type 1 Procollagen (PINP) levels in serum.

Methodology

Immunochemiluminometric assay (ICMA)

Collection instructions

Separate serum from cells within 45 minutes of collection. If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Nonserum sample received

Reference range

See table. Individuals <20 years of age Not established Pre-menopausal females 13.9–89.1 ng/mL Post-menopausal females 10.4–97.8 ng/mL Males ≤ 45 years of age 21.8–96.0 ng/mL Male > 45 years of age 18.3–86.1 ng/mL

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. When evaluating subsequent samples, collect the samples at the same time of the day, as there is a diurnal variation of P1NP with the values being higher at night. The measurement of P1NP has limited specificity as it is reflective of the rate of bone turnover in general. Type I collagen is synthesized by fibroblasts and therefore can be found in loose connective tissues together with other collagen types. However, since bone is the major collagenous organ and also metabolically active throughout life, the majority of the circulating…

LOINC map

Result codeResult nameUnitsResult LOINC
140856Propeptide Type I Collagenng/mL47255-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82523

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.