Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Thyroid-stimulating Immunoglobulin (TSI)

Thyroid-stimulating Immunoglobulin (TSI): Labcorp test 140749

Labcorp test 140749, CPT 84445. Specimen: Serum (preferred) or plasma (EDTA or heparin). Turnaround: 2 - 4 days.

Thyroid-stimulating Immunoglobulin (TSI) is Labcorp test code 140749, billed with CPT 84445. Specimen: Serum (preferred) or plasma (EDTA or heparin). Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140749
CPT84445
LOINC30567-2
SpecimenSerum (preferred) or plasma (EDTA or heparin)
Volume1 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, lavender-top (EDTA) tube or green-top (heparin) tube
Turnaround time2 - 4 days

Also known as: Human Thyroid Stimulator (HTS); Long-acting Thyroid Stimulator (LATS)

Use

The measurement of thyroid stimulating autoantibodies, in conjunction with other clinical and laboratory findings, is used as an aid in the diagnosis of patients suspected of having Graves' disease.

Methodology

The IMMULITE 2000 TSI assay designed for the specific Semi- Quantitative detection of stimulating autoantibodies using a bridging format and human TSH receptor fragment chimeric recombinant proteins. The capture and detection proteins are designed to be specific for antibodies that stimulate the native receptor. This method provides a determination of thyroid stimulating autoantibodies that are specific to TSH receptors in human serum or plasma. The assay is traceable to WHO NIBSC 08/204.

Collection instructions

Serum or plasma must be separated from blood cells by centrifugation, ideally within two hours of collection. If red-top tube or plasma, transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

Prepare sterile venipuncture site.

Causes for rejection

Gross lipemia

Reference range

0.00-0.55 IU/L

Limitations

Heterophilic antibodies in human serum can react with the immunoglobulins included in the assay components causing interference with in vitro immunoassays. For diagnostic purposes, the results obtained from this assay should be used in combination with the clinical examination, patient medical history, and other findings.

LOINC map

Result codeResult nameUnitsResult LOINC
140754Thyroid Stim ImmunoglobulinIU/L30567-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84445

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation