Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Neuron-specific Enolase (NSE)

Neuron-specific Enolase (NSE): Labcorp test 140624

Labcorp test 140624, CPT 86316. Specimen: Serum. Turnaround: 3 - 10 days.

Neuron-specific Enolase (NSE) is Labcorp test code 140624, billed with CPT 86316. Specimen: Serum. Turnaround time: 3 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140624
CPT86316
LOINC57371-7
SpecimenSerum
Volume0.5 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 10 days
Storage / transportRefrigerate.

Use

An aid in the detection and monitoring of neuroendocrine tumors (NETs), particularly those associated with small-cell lung cancer (SCLC)

Methodology

The ThermoFisher/BRAHMS KRYPTOR® assay employs Time-Resolved Amplified Cryptate Emission (TRACE) technology based on a non-radioactive energy transfer between a donor (europium cryptate) and an acceptor (XL665) in a sandwich immunofluorescent format using two mouse monoclonal antibodies.

Collection instructions

Transfer separated serum to a plastic transport tube as quickly as possible after the clot has formed (within 30 minutes of collection).

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Hemolysis; gross icterus; plasma specimen

Reference range

0.0−17.6 ng/mL

Special instructions

Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 480137 to order.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. Because erythrocytes a contain large amount of NSE, hemolysis can cause falsely elevated levels.

LOINC map

Result codeResult nameUnitsResult LOINC
140690Neuron-specific Enolase, Serumng/mL57371-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86316

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation