Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Cancer Antigen (CA) 27.29

Cancer Antigen (CA) 27.29: Labcorp test 140293

Labcorp test 140293, CPT 86300. Specimen: Serum. Turnaround: 2 - 3 days.

Cancer Antigen (CA) 27.29 is Labcorp test code 140293, billed with CPT 86300. Specimen: Serum. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140293
CPT86300
LOINC17842-6
SpecimenSerum
Volume1 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 3 days Within 1 day 2 - 3 days
Storage / transportRefrigerate.

Also known as: CA 27.29 Antigen; Truquant BR

Use

This test is used to manage patients with metastatic carcinoma of the breast.

Methodology

Immunochemiluminometric assay (ICMA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Refrigerated5 days
Frozen>1 month

Causes for rejection

Room temperature specimen received; plasma other than EDTA plasma

Reference range

0−38.6 units/mL

Special instructions

Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please order the serial monitoring test ( 480293 ).

Limitations

For the quantitative determination of CA 27.29 antigen in serum of patients previously treated for stage II or stage III breast cancer, serial testing for CA 27.29 antigen in patients who are clinically free of disease should be used in conjunction with other clinical methods for the early detection of recurrence.

LOINC map

Result codeResult nameUnitsResult LOINC
142134CA 27.29U/mL17842-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86300

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation