Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Mpox (Orthopoxvirus), DNA, PCR

Mpox (Orthopoxvirus), DNA, PCR: Labcorp test 140230

Labcorp test 140230, CPT 87593. Specimen: Lesion swab. Turnaround: 3 - 4 days.

Mpox (Orthopoxvirus), DNA, PCR is Labcorp test code 140230, billed with CPT 87593. Specimen: Lesion swab. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140230
CPT87593
LOINC100434-0
SpecimenLesion swab
VolumeOne swab in UTM or VTM
Minimum volumeOne swab in UTM or VTM
ContainerUniversal Transport Media (UTM) or Viral Transport Media (VTM)
Turnaround time3 - 4 days
Storage / transportRefrigerate.

Also known as: Monkeypox Virus PCR

Use

Vesicular specimens collected from persons infected with a non-variola Orthopoxvirus (such as vaccinia, mpox, or cowpox) are expected to produce a positive result with this assay. Although this assay does not differentiate vaccinia or mpox virus from cowpox, camelpox, ectromelia or gerbilpox virus, a positive result with this assay in the United States is most likely due to mpox virus or vaccinia virus. However, potential exposure to other Orthopoxviruses should be considered.

Methodology

Polymerase chain reaction (PCR)

Collection instructions

Vigorously swab or brush the base of the lesion with a sterile dry polyester, rayon or Dacron swab. Insert the swab into the tube containing UTM or VTM. Carefully break the swab at the scoreline and tightly close the sample. Some UTM kits may contain two swabs; however, only one swab needs to be collected and submitted for testing. If multiple lesions with differing appearances are present, consider submitting an additional UTM/VTM collection, as described above, for each lesion.

Stability

TemperaturePeriod
Refrigerated7 days (stability provided by manufacturer or literature reference)
Frozen30 days (stability provided by manufacturer or literature reference)

Causes for rejection

Improperly submitted specimens, including grossly leaking samples; swabs submitted in non-validated transport media, including 0.9% saline or liquid Amies (E-Swabs); swab specimens submitted in aerobic or anaerobic transport devices

Limitations

A false negative result may occur if a sample is improperly collected, transported or handled. False negative results may occur if the quantity of viral DNA present in the sample is below the limit of detection for the assay. An inconclusive result may be returned if the lesion is not adequately sampled.

LOINC map

Result codeResult nameUnitsResult LOINC
140231Orthopoxvirus DNA100434-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87593

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation