Troponin T (Highly Sensitive): Labcorp test 140150
Labcorp test 140150, CPT 84484. Specimen: Plasma (lithium-heparin), frozen. Turnaround: 1 - 3 days.
Also known as: Cardiac Troponin T
Use
Immunoassay for the in vitro quantitative determination of cardiac troponin T (cTnT) in lithium heparin plasma. The immunoassay is intended to aid in the diagnosis of myocardial infarction.
Methodology
Electrochemiluminescence immunoassay (ECLIA)
Collection instructions
Centrifuge and transfer separated heparin plasma to a plastic transport tube and label as Li-Heparin plasma. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .
Stability
| Temperature | Period |
|---|---|
| Refrigerated | 24 hours (stability provided by manufacturer or literature reference) |
| Frozen | 12 months (stability provided by manufacturer or literature reference) |
| Freeze/thaw cycles | Stable x1 (stability provided by manufacturer or literature reference) |
Causes for rejection
Sample other than lithium heparin plasma
Reference range
See table. Age Male (ng/L) Female (ng/L) All
Special instructions
This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Limitations
For diagnostic purposes, the results should always be assessed in conjunction with the patient’s medical history, clinical examination and other findings. The Universal Definition of AMI takes into consideration the ESC/ACC/AHA/WHF definition recommending the detection of a rise and/or fall of cardiac troponin in the clinical setting with at least one value above the 99th percentile upper reference limit. Due to the release kinetics of cardiac troponin T, an initial test result may not be definitive in diagnosing MI. Serial cardiac troponin measurements are suggested. Troponins are released during the process of myocyte necrosis. While they are cardiac-specific, they are not specific for…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 140164 | Troponin T(Highly Sensitive) | ng/L | 67151-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 84484
- High Sensitivity Troponin T
- Troponin I, High Sensitivity, Plasma (Pediatric Neurology)
- Troponin T (cTnT) 5th Generation
- Troponin T, High-Sensitivity