Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Influenza A/H5 Subtyping, NAA

Influenza A/H5 Subtyping, NAA: Labcorp test 140111

Labcorp test 140111, CPT 87501. Specimen: Nasopharyngeal swab. Turnaround: 2 - 4 days.

Influenza A/H5 Subtyping, NAA is Labcorp test code 140111, billed with CPT 87501. Specimen: Nasopharyngeal swab. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code140111
CPT87501
LOINC38272-1
SpecimenNasopharyngeal swab
Volume1 swab
Minimum volume1 swab
ContainerUniversal or Viral Transport Media (UTM or VTM)
Turnaround time2 - 4 days
Storage / transportFreeze.

Also known as: Avian influenza; Bird flu

Use

This test detects influenza A/H5 subtype by nucleic acid amplification.

Methodology

Nucleic Acid Amplification

Collection instructions

Collect NP swab per standard techniques and immediately place swab in 3 mL of UTM or VTM.

Stability

TemperaturePeriod
Room temperature24 hours
Refrigerated3 days
Frozen14 days
Freeze/thaw cyclesStable x2

Causes for rejection

Improper collection; inadequate specimen; improper labeling; specimen leaked in transit; quantity not sufficient for analysis; name discrepancies; specimen exceeding storage requirements; nasal swabs or any other upper respiratory sample other than nasopharyngeal swab in universal or viral transport media; samples submitted in non-approved transport devices

Special instructions

This test currently is not approved for use in New York state.

Limitations

This test detects sequences for influenza A and the H5 subtype. Influenza A/H5 is currently very rarely found in humans in the United States. Results from this test must be correlated with the clinical history, epidemiological data and other data available to the clinician evaluating the patient. Viral and bacterial nucleic acids may persist in vivo independent of organism viability. Detection of organism target(s) does not imply that the corresponding organisms are infectious or are the causative agents for clinical symptoms. The detection of viral and bacterial nucleic acid is dependent upon proper specimen collection, handling, transportation, storage and preparation. Failure to observe…

LOINC map

Result codeResult nameUnitsResult LOINC
Influenza A/H5 Subtype, NAA140107H5 subtype38272-1

View this test on Labcorp's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation