Labcorp test 140045, CPT 81500. Specimen: Serum. Turnaround: 1 - 3 days.

Ovarian Malignancy Risk (ROMA®) is Labcorp test code 140045, billed with CPT 81500. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140045 (Women's Health)
CPT81500
LOINC10334-1, 55180-4
SpecimenSerum
Volume1.75 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 3 days
Storage / transportRefrigerate; stable for 5 days at room temperature or 14 days refrigerated.

Also known as: ROMA®

Use

The ROMA™ (Risk of Ovarian Malignancy Algorithm) calculation combines the results of the Roche Elecsys HE4 assay, Elecsys CA 125 II assay and menopausal status into a numerical score (Roche). The ROMA value is intended to aid in assessing whether a premenopausal or postmenopausal woman who presents with an ovarian adnexal mass is at high or low likelihood of finding malignancy on surgery. ROMA Calculation is indicated for women who meet the following criteria: over age 18; ovarian adnexal mass present for which surgery is planned, and not yet referred to an oncologist. ROMA values must be interpreted in conjunction with an independent clinical and radiological assessment. The test is not…

Methodology

Electrochemiluminescence Immunoassay (ECLIA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Causes for rejection

Gross hemolysis

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

The Risk of Ovarian Malignancy Algorithm (ROMA) uses the combination of Elecsys HE4 and Elecsys CA 125 II assay values of a woman. The premenopausal or postmenopausal status must be based on ovarian function determined with information available from clinical evaluation and medical history. • ROMA cannot be used as absolute evidence for the presence or absence of malignant disease. • ROMA should not be used as a cancer screening test. • ROMA has only been evaluated in women who will undergo a surgical intervention and is only intended for this population. • ROMA should not be used without an independent clinical evaluation and is not intended to determine whether a patient should proceed to…

LOINC map

Result codeResult nameUnitsResult LOINC
Cancer Antigen (CA) 125U/mL10334-1
HE4pmol/L55180-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81500

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation